| Housing | Cylindrical thread design |
| Thread size | M30 x 1.5 |
| Diameter | Ø 30 mm |
| Sensing range Sn | 4 mm … 25 mm |
| Safe sensing range Sa | 18 mm |
| Installation type | Non-flush |
| Switching frequency | 10 Hz |
| Connection type | Cable, 2-wire, 2 m 1) |
| Output function | NC or NO |
| Electrical wiring | AC 2-wire |
| Adjustment | Potentiometer (Sensitivity) |
| Enclosure rating | IP67 2) |
Cơ khí/ Điện tử
| Supply voltage | 20 V AC … 250 V AC |
| Ripple | ≤ 10 % 1) |
| Voltage drop | ≤ 10 V DC 2) |
| Current consumption | 10 mA 3) |
| Time delay before availability | ≤ 100 ms |
| Hysteresis | 4 % … 20 % |
| Reproducibility | ≤ 5 % 4) 5) |
| Temperature drift (of Sr) | ± 10 % |
| EMC | According to EN 60947-5-2 6) |
| Continuous current Ia | ≤ 500 mA |
| Cable material | PVC |
| Conductor size | 0.5 mm² |
| Reverse polarity protection | ✔ |
| Power-up pulse protection | ✔ |
| Shock and vibration resistance | 30 g, 11 ms / 10 … 55 Hz, 1 mm |
| Ambient operating temperature | –25 °C … +80 °C |
| Housing material | Plastic, PBT |
| Housing length | 75.6 mm |
| Thread length | 50 mm |
| Tightening torque, max. | ≤ 7.5 Nm |
| Items supplied | Mounting nut, PA12 plastic (2x)
Screwdriver for potentiometer adjustment (1 x) |