Key Commercial Data
Orderkey | 1015526 |
---|---|
Packing unit | 1 pc |
Catalog page | Page 227 (C-6-2019) |
GTIN | 4055626496566 |
Weight per Piece (excluding packing) | 0.000 g |
Custom tariff number | 85371098 |
Country of origin | DE (Germany) |
Note
Utilization restriction | EMC: class A product, see manufacturer’s declaration in the download area |
---|
Ambient conditions
Ambient temperature (operation) | -35 °C … 60 °C (observe derating) |
---|---|
Ambient temperature (storage/transport) | -40 °C … 85 °C |
Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
Maximum altitude | ≤ 2000 m (Above sea level) |
Power supply
Designation | A1/A2 |
---|---|
Rated control circuit supply voltage US | 24 V DC -20 % / +25 % |
Rated control supply current IS | typ. 80 mA |
Power consumption at US | typ. 1.92 W |
Inrush current | typ. 28 A (Δt = 30 µs at Us) |
Filter time | 10 ms (For the logic. At A1 in the event of voltage dips at Us) |
Protective circuit | Serial protection against polarity reversal Suppressor diode |
Digital inputs
Input name | Sensor circuit |
---|---|
S12, S22 | |
Description of the input | safety-related sensor inputs |
NPN | |
Number of inputs | 2 |
Input voltage range “0” signal | 0 V DC … 5 V DC |
Input voltage range “1” signal | 11 V DC … 30 V DC |
Input current range “0” signal | 0 mA … 2 mA |
Inrush current | < 11 mA (typically with US) |
Current consumption | < 4.5 mA (typically with US) |
Filter time | max. 3 ms (Test pulse width of low test pulses) |
min. 21 ms (Test pulse rate for low test pulse) | |
Max. permissible overall conductor resistance | 150 Ω |
Concurrence input 1/2 | ∞ |
Limit frequency | min. 0 Hz |
max. 1 Hz | |
Protective circuit/component | Varistor |
Input name | Start circuit |
S34 | |
Description of the input | non-safety-related |
NPN | |
Number of inputs | 1 |
Input voltage range “0” signal | 0 V DC … 5 V DC |
Input voltage range “1” signal | 11 V DC … 30 V DC |
Input current range “0” signal | 0 mA … 2 mA |
Inrush current | < 8.6 mA (typically with US) |
Current consumption | < 3.2 mA (typically with US) |
Filter time | max. 3 ms (Test pulse width of low test pulses) |
min. 21 ms (Test pulse rate for low test pulse) | |
Max. permissible overall conductor resistance | 150 Ω |
Limit frequency | min. 0 Hz |
max. 1 Hz | |
Protective circuit/component | Varistor |
Relay outputs: enabling current path
Output name | Enabling current paths |
---|---|
13/14, 23/24/34, 47/48/58 | |
Output description | 2 N/O contacts each in series, safety-related, floating |
Number of outputs | 3 (undelayed: 13/14, 23/24/34) |
2 (delayed: 47/48/58) | |
Contact type | 5 enabling current paths |
Contact material | AgSnO2 |
Switching voltage | min. 12 V AC/DC |
max. 250 V AC (Observe the load curve) | |
Limiting continuous current | 6 A |
Inrush current | min. 3 mA |
max. 6 A | |
Sq. Total current | 108 A2(observe derating) |
Switching capacity | min. 60 mW |
Switching frequency | 0.5 Hz (depending on the set delay time) |
Mechanical service life | 10x 106cycles |
Switching capacity according to IEC 60947-5-1 | 4 A (24 V (DC13)) |
5 A (250 V (AC15)) | |
Output fuse | 6 A gL/gG |
4 A gL/gG (for low-demand applications) |
Alarm outputs
Designation | M1 |
---|---|
Output description | PNP |
non-safety-related | |
Number of outputs | 1 |
Voltage | approx. 23 V DC (US– 1 V) |
Current | max. 100 mA |
Maximum inrush current | 500 mA (Δt = 10 ms at Us) |
Protective circuit/component | Suppressor diode |
Short-circuit protection | Yes |
Clock outputs
Designation | S11, S21 |
---|---|
Output description | PNP |
non-safety-related | |
Number of outputs | 2 |
Voltage | corresponds to US |
Current | max. 100 mA |
Maximum inrush current | 500 mA (Δt = 10 ms at Us) |
Cable length | max. 150 m |
Protective circuit/component | Suppressor diode |
Short-circuit protection | Yes |
Times
Typical pickup time at US | 500 ms (with Uswhen controlled via A1) |
---|---|
Typical response time at US | < 40 ms (automatic start) |
< 30 ms (manual, monitored start) | |
Typical release time at US | < 25 ms (when controlled via S12 and S22 (only for undelayed contacts)) |
< 5 ms (when controlled via A1; applicative deactivation via A1/A2 is not permitted) | |
Delay time range | 0.2 s … 300 s ±5 % (can be set for 47/48/58) |
Restart time | < 1 s (Boot time) |
Recovery time | 500 ms (following demand of the safety function) |
General
Relay type | Electromechanical relay with forcibly guided contacts in accordance with IEC/EN 61810-3 (EN 50205) |
---|---|
Nominal operating mode | 100% operating factor |
Net weight | 155.43 g |
Mounting position | vertical or horizontal |
Mounting type | DIN rail mounting |
Assembly instructions | See derating curve |
Degree of protection | IP20 |
Min. degree of protection of inst. location | IP54 |
Housing material | PBT |
Housing color | yellow |
Status display | 5 x bi-color LED |
Connection capacity
Connection method | Push-in spring connection |
---|---|
pluggable | Yes |
Conductor cross section solid | 0.2 mm² … 1.5 mm² |
Conductor cross section flexible | 0.2 mm² … 1.5 mm² |
Conductor cross section AWG / kcmil | 24 … 16 |
Conductor cross section flexible, with ferrule without plastic sleeve | 0.25 mm² … 1.5 mm² (only together with CRIMPFOX 6) |
Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.25 mm² … 1.5 mm² (only together with CRIMPFOX 6) |
Stripping length | 8 mm |
Safety-related characteristic data
Stop category | 0 |
---|---|
1 | |
Designation | IEC 61508 – High demand |
Safety Integrity Level (SIL) | 3 |
Designation | IEC 61508 – Low demand |
Safety Integrity Level (SIL) | 3 |
Designation | EN ISO 13849 |
Performance level (PL) | e (4 A DC13; 5 A AC15; 8760 switching cycles/year) |
Category | 4 |
Designation | EN 62061 |
Safety Integrity Level Claim Limit (SIL CL) | 3 |
Standards and Regulations
Designation | Air clearances and creepage distances between the power circuits |
---|---|
Standards/regulations | DIN EN 50178 |
Rated insulation voltage | 250 V AC |
Rated surge voltage/insulation | Basic insulation 4 kV between all current paths and housing |
Safe isolation, reinforced insulation 6 kV between (A1, A2, S11, S12, S21, S22, S34, M1) and enabling current path (13/14) and enabling current path (23/24/34) and enabling current path (47/48/58) | |
Degree of pollution | 2 |
Overvoltage category | III |
Shock | 10g (operation), 15g (transport) |
Vibration (operation) | 10 Hz … 150 Hz, 2g |
Conformance | CE-compliant |
Environmental Product Compliance
REACh SVHC | Lead 7439-92-1 |
---|---|
China RoHS | Environmentally Friendly Use Period = 50 |
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer’s declaration” |