Key Commercial Data
Orderkey | 2902659 |
---|---|
Packing unit | 1 pc |
Catalog page | Page 336 (C-6-2017) |
GTIN | 4046356669696 |
Weight per Piece (excluding packing) | 120.000 g |
Custom tariff number | 85176200 |
Country of origin | DE (Germany) |
Note
Utilization restriction | EMC: class A product, see manufacturer’s declaration in the download area |
---|
Ambient conditions
Ambient temperature (operation) | -40 °C … 65 °C |
---|---|
Ambient temperature (storage/transport) | -40 °C … 85 °C |
Permissible humidity (operation) | 30 % … 95 % (non-condensing) |
Permissible humidity (storage/transport) | 30 % … 95 % (non-condensing) |
Altitude | 5000 m (For restrictions see manufacturer’s declaration) |
2000 m (With UL approval) | |
Degree of protection | IP20 |
General
Electrical isolation | according to IEEE 802.3 |
---|---|
VCC // FE // Ethernet | |
Latency | ± 1.3 µs (Store&Forward mode, 10/100 Mbps, depending on the frame size) |
Test voltage data interface/power supply | 1.5 kVrms(50 Hz, 1 min.) |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Net weight | 120 g |
Housing material | PA 6.6-FR |
Color | green |
MTBF | 492 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day)) |
133 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day)) | |
Conformance | CE-compliant |
ATEX | II 3 G Ex nA IIC T4 Gc X (Please follow the special installation instructions in the documentation!) |
UL, USA/Canada | cULus listed UL 508 |
Class I, Zone 2, AEx nA IIC T4 | |
Class I, Zone 2, Ex nA IIC T4 Gc X | |
Class I, Div. 2, Groups A, B, C, D |
Power supply
Nominal supply voltage | |
---|---|
Supply voltage range | 18 V DC … 30 V DC (Screw connection) |
18 V DC … 30 V DC (as an alternative or redundant, via backplane bus contact and system current supply) | |
Typical current consumption | < 110 mA (24 V DC) |
Protective circuit | Reverse polarity protection |
Connection method | Plug-in screw terminal block (COMBICON), redundancy possible |
Conductor cross section flexible max. | 2.50 mm² |
Conductor cross section flexible min. | 0.20 mm² |
Conductor cross section solid max. | 2.50 mm² |
Conductor cross section solid min. | 0.20 mm² |
Max. AWG conductor cross section, flexible | 14 |
Min. AWG conductor cross section, flexible | 24 |
Conductor cross section AWG max. | 14 |
Conductor cross section AWG min. | 24 |