Key Commercial Data
Orderkey | 2858991 |
---|---|
Packing unit | 1 pc |
Catalog page | Page 97 (TT-2005) |
GTIN | 4017918920463 |
Weight per Piece (excluding packing) | 139.800 g |
Custom tariff number | 85363010 |
Country of origin | DE (Germany) |
General
Housing material | Aluminum, anodized |
---|---|
Color | black |
Standards for cearances and creepage distances | DIN VDE 0110-1 |
IEC 60664-1 | |
Overvoltage category | II |
Degree of pollution | 2 |
Mounting type | Connection-specific intermediate plugging |
Type | Attachment plug |
Direction of action | Line-Line & Line-Shield & Shield-Earth Ground |
Protective circuit
IEC test classification | C1 |
---|---|
C2 | |
C3 | |
B2 | |
B3 | |
VDE requirement class | C1 |
C2 | |
C3 | |
B2 | |
B3 | |
Maximum continuous voltage UC | ± 7 V DC |
Rated current | 1.5 A (25 °C) |
Operating effective current ICat UC | ≤ 100 µA |
Residual current IPE | ≤ 100 µA |
Nominal discharge current In(8/20) µs (line-line) | 350 A |
Nominal discharge current In(8/20) µs (line-earth) | 2.5 kA |
Max. discharge current Imax(8/20) µs maximum (line-earth) | 2.5 kA (in total) |
Nominal pulse current Ian (10/700) µs (line-line) | 160 A |
Nominal pulse current Ian (10/700) µs (line-earth) | 160 A |
Output voltage limitation at 1 kV/µs (line-line) spike | ≤ 22 V |
Output voltage limitation at 1 kV/µs (line-earth) spike | ≤ 80 V (equipotential bonding lead: 1 m) |
Output voltage limitation at 1 kV/µs (shield-earth) spike | ≤ 700 V (equipotential bonding lead: 1 m) |
Residual voltage at In(line-line) | ≤ 45 V |
Residual voltage at In(line-earth) | ≤ 45 V |
Residual voltage at In(shield-earth) | ≤ 700 V |
Voltage protection level Up(line-line) | ≤ 50 V (C1 – 500 V / 250 A) |
≤ 20 V (B3 – 2 kV / 25 A) | |
Voltage protection level Up(line-earth) | ≤ 65 V (C1, 500 V/250 A – PA-Ltg: 1 m) |
≤ 25 V (B3 – 2 kV / 25 A – PA-Ltg: 1 m) | |
≤ 60 V (C3, 7 kV/90 A – PA-Ltg: 1 m) | |
Voltage protection level Up(shield-ground) | ≤ 850 V (C2 – 4 kV/2 kA – PA-Ltg: 1 m) |
Response time tA(line-line) | ≤ 500 ns |
Response time tA(line-earth) | ≤ 100 ns |
Input attenuation aE, sym. | 1 dB (up to 100 MHz, 100 Ω system) |
Input attenuation aE, asym. | |
Near-end crosstalk attenuation | 36 dB (pair 3-6 against pair 4-5 in 100 Ω system / 100 MHz) |
40 dB (all other pair combinations in 100 Ω system/100 MHz) | |
Cut-off frequency fg (3 dB), sym. in 100 Ohm system | ≤ 100 MHz |
Capacity (line-line) | 20 pF (typical) |
Capacity (line-earth) | 1 pF (typical) |
Surge protection fault message | none |
Impulse durability (line-line) | B2 – 4 kV/100 A |
B3 – 2 kV / 25 A | |
C1 – 500 V / 250 A | |
Impulse durability (line-earth) | B2 – 4 kV/100 A |
C1 – 500 V / 250 A | |
C2 – 4 kV/2 kA | |
B3 – 2 kV / 25 A |
Connection data
Connection method | RJ45 |
---|---|
Connection method IN | RJ45 socket |
Connection method OUT | RJ45 socket |
Connection technology | Network interfaces (e.g. Ethernet, Token Ring and CDDI/FDDI) |