Key Commercial Data
| Orderkey | 2702636 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 320 (C-6-2017) |
| GTIN | 4055626251530 |
| Weight per Piece (excluding packing) | 74.650 g |
| Custom tariff number | 85389091 |
| Country of origin | DE (Germany) |
Note
| Utilization restriction | EMC: class A product, see manufacturer’s declaration in the download area |
|---|
Ambient conditions
| Ambient temperature (operation) | -40 °C … 70 °C |
|---|---|
| Ambient temperature (storage/transport) | -40 °C … 85 °C |
| Permissible humidity (operation) | 10 % … 95 % (non-condensing) |
| Altitude | ≤ 5000 m (For restrictions see manufacturer’s declaration) |
| ≤ 2000 m (When used in EX zone 2) | |
| Degree of protection | IP20 |
General
| Electrical isolation | DIN EN 50178 (RS-485 // VCC) |
|---|---|
| Test voltage data interface/power supply | 1.5 kV AC (50 Hz, 1 min.) |
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
| Net weight | 74.65 g |
| Housing material | PA 6.6-FR |
| Color | green |
| MTTF | 3305 Years (SN 29500 standard, temperature 25 °C, operating cycle 21 % (5 days a week, 8 hours a day)) |
| 1923 Years (SN 29500 standard, temperature 40 °C, operating cycle 34.25 % (5 days a week, 12 hours a day)) | |
| 911 Years (SN 29500 standard, temperature 40 °C, operating cycle 100 % (7 days a week, 24 hours a day)) | |
| Degree of pollution | 2 |
| Overvoltage category | II |
| Conformance | CE-compliant |
| ATEX | II 3 G Ex nA IIC T4 Gc X (Please follow the special installation instructions in the documentation!) |
| UL, USA/Canada | 508 Listed |
Power supply
| Nominal supply voltage | 24 V DC (via pluggable COMBICON screw terminal block) |
|---|---|
| Supply voltage range | 18 V DC … 30 V DC (via pluggable COMBICON screw terminal block) |
| Max. current consumption | 12 mA (18 V DC, no load on D-SUB) |
| 77 mA (18 V DC, current drain at D-SUB of 150 mA) | |
| Typical current consumption | 10 mA (24 V DC, no load on D-SUB) |
| 60 mA (24 V DC, current drain at D-SUB of 150 mA) | |
| Conductor cross section flexible max. | 2.50 mm² |
| Conductor cross section flexible min. | 0.20 mm² |
| Conductor cross section solid max. | 2.50 mm² |
| Conductor cross section solid min. | 0.20 mm² |
| Max. AWG conductor cross section, flexible | 12 |
| Min. AWG conductor cross section, flexible | 24 |