Features
Functional principle Photoelectric proximity sensor Functional principle detail Background suppression, TwinEye technology Sensing range Sensing range min. 10 mm Sensing range max. 1,000 mm Adjustable switching threshold for background suppression 150 mm … 1,000 mm Reference object Object with 90% remission (based on standard white, DIN 5033) Minimum distance between set sensing range and background (black 6% / white 90%) 25 mm, at a distance of 500 mm Recommended sensing range for the best performance 200 mm … 500 mm Emitted beam Light source PinPoint LED Type of light Visible red light Shape of light spot Point-shaped Light spot size (distance) Ø 10 mm (550 mm) Maximum dispersion of the emitted beam around the standardized transmission axis (squint angle) < +/- 1.0° (at Ta = +23 °C) Key LED figures Normative reference EN 62471:2008-09 | IEC 62471:2006, modified LED risk group marking Free group Wave length 635 nm Average service life 100,000 h at Ta = +25 °C Adjustment Teach-Turn adjustment BluePilot: For setting the sensing range IO-Link For configuring the sensor parameters and Smart Task functions Indication LED blue BluePilot: sensing range indicator LED green Operating indicator
Static on: power on
Flashing: IO-Link modeLED yellow Status of received light beam
Static on: object present
Static off: object not presentSpecial applications Detecting uneven, shiny objects, Detecting objects wrapped in film
-
Safety-related parameters
MTTFD 415 years DCavg 0 % TM (mission time) 20 years (EN ISO 13849)
Rate of use: 60 %
-
Communication interface
IO-Link ✔ , V1.1 Data transmission rate COM2 (38,4 kBaud) Cycle time 2.3 ms Process data length 16 Bit Process data structure Bit 0 = switching signal QL1 Bit 1 = switching signal QL2 Bit 2 … 15 = empty VendorID 26 DeviceID HEX 0x80017D DeviceID DEC 8388989 Compatible master port type A SIO mode support Yes
-
Electrical data
Supply voltage UB 10 V DC … 30 V DC 1) Ripple ≤ 5 Vpp Usage category DC-12 (According to EN 60947-5-2)
DC-13 (According to EN 60947-5-2)
Current consumption ≤ 30 mA, without load. At UB = 24 V Protection class III Digital output Type Push-pull: PNP/NPN Signal voltage PNP HIGH/LOW Approx. UB-2.5 V / 0 V Signal voltage NPN HIGH/LOW Approx. UB / < 2.5 V Output current Imax. ≤ 100 mA Circuit protection outputs Reverse polarity protected Overcurrent and short-circuit protected Response time ≤ 1.4 ms 2) Repeatability (response time) 750 µs Switching frequency 350 Hz 3) Pin/Wire assignment Function of pin 4/black (BK) Digital output, QL1, IO-Link communication C (see document no. 8022709, 8021940) Function of pin 4/black (BK) – detail The pin 4 function of the sensor can be configured, Additional possible settings via IO-Link Function of pin 2/white (WH) Digital input (see document no. 8022709, 8021940) Function of pin 2/white (WH) – detail The pin 2 function of the sensor can be configured, Additional possible settings via IO-Link - 1) Limit values.
- 2) Signal transit time with resistive load in switching mode.
- 3) With light/dark ratio 1:1.
-
Mechanical data
Housing Rectangular Dimensions (W x H x D) 24.6 mm x 82.5 mm x 53.3 mm Connection Male connector M12, 4-pin Material Housing Plastic, VISTAL® Front screen Plastic, PMMA Male connector Plastic, VISTAL® Weight Approx. 80 g Maximum tightening torque of the fixing screws 1.3 Nm
-
Ambient data
Enclosure rating IP66 (EN 60529)
IP67 (EN 60529)
IP69 (EN 60529) 1)
Ambient operating temperature –40 °C … +60 °C Ambient temperature, storage –40 °C … +75 °C Shock resistance 50 g, 11 ms (25 positive and 25 negative shocks per axis, for X, Y, Z axes, 150 shocks in total (EN60068-2-27))
50 g, 6 ms (5,000 positive and 5,000 negative shocks per axis, for X, Y, Z axes, 30,000 shocks in total (EN60068-2-27))
Vibration resistance 10 Hz … 2,000 Hz (Amplitude 0.5 mm / 10 g, 20 sweeps per axis, for X, Y, Z axes, 1 octave/min, (EN60068-2-6)) Air humidity 35 % … 95 %, Relative humidity (no condensation) Electromagnetic compatibility (EMC) EN 60947-5-2 Resistance to cleaning agent ECOLAB UL File No. NRKH.E181493 & NRKH7.E181493 - 1) Replaces IP69K with ISO 20653: 2013-03.
-
Smart Task
Smart Task name Time measurement + debouncing Logic function Direct
WINDOW
Timer function Deactivated
On delay
Off delay
ON and OFF delay
Impulse (one shot)
Inverter Yes Response time 1) Repeatability 1) Time measurement accuracy SIO Logic: – 1,65 … + 1,65 ± 0,5 % of time measurement value 2)
IOL: – 1.8 … + 1.8 ms ± 0.5% of the time measurement 3)
Time measurement accuracy (e.g. accuracy for time measurement value = 1 s ) SIO Logic: – 6,8 … + 6,8 ms 2)
IOL: – 6,8 … + 6,8 ms 3)
Resolution time measuring value 1 ms Min. Time between two process events (switches) SIO Logic: 1,25 ms
IOL: 1,55 ms
Debounce time max. SIO Logic: 30.000 ms 2)
IOL: 30.000 ms 3)
Switching signal Switching signal QL1 Output type (dependant on the adjusted threshold) Measuring value Time measurement value - 1) Use of Smart Task functions with IO-Link communication function.
- 2) SIO Logic: Sensor operation in standard I/O mode without IO-Link communication. Sensor-internal logic or timing parameters plus Automation Functions used.
- 3) IOL: Sensor operation with full IO-Link communication and usage of logic, timing and Automation Function parameters.
-
Diagnosis
Device status Yes Quality of teach Yes
-
Classifications
eCl@ss 5.0 27270904 eCl@ss 5.1.4 27270904 eCl@ss 6.0 27270904 eCl@ss 6.2 27270904 eCl@ss 7.0 27270904 eCl@ss 8.0 27270904 eCl@ss 8.1 27270904 eCl@ss 9.0 27270904 eCl@ss 10.0 27270904 eCl@ss 11.0 27270904 eCl@ss 12.0 27270903 ETIM 5.0 EC002719 ETIM 6.0 EC002719 ETIM 7.0 EC002719 ETIM 8.0 EC002719 UNSPSC 16.0901 39121528