Features
Functional principle Photoelectric retro-reflective sensor Functional principle detail Autocollimation Sensing range max. 0 m … 4.5 m 1)
2)
Sensing range 0 m … 2 m 1)
2)
Polarisation filters Yes Emitted beam Light source Laser 3) Type of light Visible red light Light spot size (distance) Ø 1 mm (500 mm) Key laser figures Normative reference EN 60825-1:2014, IEC 60825-1:2014 / CDRH 21 CFR 1040.10 & 1040.11 Laser class 1 Wave length 650 nm Adjustment Single teach-in button Special applications Hygienic and washdown zones, Detecting transparent objects, Detecting small objects Housing design Washdown 4) Mounting hole M3 - 1) Reflective tape REF-AC1000.
- 2) To ensure reliable operation, we recommend using REF-AC1000 reflective tape or reflective-tap reflectors such as P41F, PLV14-A, PLH25-M12, or PLH25-D12. Reflectors with large-scale triple structures must only be used if deemed suitable for the application.
- 3) Average service life: 50,000 h at TU = +25 °C.
- 4) Difference between standard/washdown and hygiene: The essential difference between a standard/washdown product and a hygiene product is that where the process and contact with the medium (activity in the vicinity of the food) are concerned, a hygiene product is designed in accordance with the latest standards and hygiene design guidelines, and materials are selected accordingly.
-
Safety-related parameters
MTTFD 582 years (EN ISO 13849-1) 1) DCavg 0 % - 1) Mode of calculation: Parts-Count-calculation.
-
Electrical data
Supply voltage UB 10 V DC … 30 V DC 1) Ripple < 5 Vpp 2) Current consumption 30 mA 3) Protection class III Digital output Type PNP 4) Output current Imax. ≤ 100 mA Response time ≤ 0.5 ms 5) Switching frequency 1,000 Hz 6) Switching mode Light/dark switching 4) Output function Complementary Circuit protection A 7)
B 8)
C 9)
Special feature Detecting transparent objects - 1) Limit values when operated in short-circuit protected network: max. 8 A.
- 2) May not exceed or fall below Uv tolerances.
- 3) Without load.
- 4) Q = light switching.
- 5) Signal transit time with resistive load.
- 6) With light/dark ratio 1:1.
- 7) A = VS connections reverse-polarity protected.
- 8) B = inputs and output reverse-polarity protected.
- 9) C = interference suppression.
-
Mechanical data
Housing Rectangular Design detail Slim Dimensions (W x H x D) 15.3 mm x 55.4 mm x 22.2 mm Connection Cable, 4-wire, 5 m 1) Connection detail Conductor size 0.14 mm² Length of cable (L) 5 m 1) Material Housing Stainless steel, Stainless steel V4A (1.4404, 316L) Front screen Plastic, PMMA Cable PVC Weight 80 g - 1) Do not bend below 0 °C.
-
Ambient data
Enclosure rating IP66
IP67
IP68
IP69K 1)
Ambient operating temperature –10 °C … +50 °C Ambient operating temperature extended –30 °C … +55 °C 2) 3) Ambient temperature, storage –30 °C … +70 °C RoHS certificate ✔ - 1) Only in case of correctly mounted IP69K connecting cable.
- 2) As of Ta = 50 °C, a max. supply voltage Vmax. = 24 V and a max. load current Imax. = 50 mA is permitted.
- 3) Operation below Tu –10 °C is possible if the sensor is already switched on at Tu > –10 °C, then cools down, and the supply voltage is subsequently not switched off. Switching on below Tu –10 °C is not permissible.
-
Classifications
eCl@ss 5.0 27270902 eCl@ss 5.1.4 27270902 eCl@ss 6.0 27270902 eCl@ss 6.2 27270902 eCl@ss 7.0 27270902 eCl@ss 8.0 27270902 eCl@ss 8.1 27270902 eCl@ss 9.0 27270902 eCl@ss 10.0 27270902 eCl@ss 11.0 27270902 eCl@ss 12.0 27270902 ETIM 5.0 EC002717 ETIM 6.0 EC002717 ETIM 7.0 EC002717 ETIM 8.0 EC002717 UNSPSC 16.0901 39121528