Mechanics/electronics
Supply voltage Vs DC 10 V … 30 V 1) Power consumption ≤ 1.2 W 2) Initialization time < 300 ms Design Cylindrical Housing material Metal (nickel-plated brass, PBT)
Plastic (ultrasonic transducer: polyurethane foam, glass epoxy resin)
Thread size M18 x 1 Connection type Male connector, M12, 5-pin Indication 2 x LED Weight 55 g Sending axis Straight Dimensions (W x H x D) 18 mm x 18 mm x 73.3 mm Enclosure rating IP65 / IP67 - 1) Limit values, reverse-polarity protected, operation in short-circuit protected network: max. 8 A.
- 2) Without load.
-
Performance
Operating range, limiting range 30 mm … 250 mm, 350 mm Target Natural objects Resolution ≥ 0.08 mm Repeatability ± 0.15 % 1) Accuracy ≤ 2 % 2) Response time 32 ms Output time 8 ms Ultrasonic frequency (typical) 320 kHz Detection area (typical) See diagrams Additional function Teach-in of analog output, Invertable analog output, Multi functional input: external teach / synchronization of up to 10 sensors, reset to factory default - 1) In relation to the current measured value, minimum value ≥ resolution.
- 2) Referring to current measurement value.
-
Interfaces
Analog output Number 1 Type Current output Current 4 mA … 20 mA, ≤ 500 Ω 1) Resolution 12 bit Multifunctional input (MF) 1 x - 1) For 4 mA … 20 mA and Vs ≤ 20 V max. load ≤ 100 Ω.
-
Ambient data
Ambient temperature, operation –25 °C … +70 °C Ambient temperature, storage –40 °C … +85 °C
-
Classifications
ECl@ss 5.0 27270804 ECl@ss 5.1.4 27270804 ECl@ss 6.0 27270804 ECl@ss 6.2 27270804 ECl@ss 7.0 27270804 ECl@ss 8.0 27270804 ECl@ss 8.1 27270804 ECl@ss 9.0 27270804 ECl@ss 10.0 27270804 ECl@ss 11.0 27270804 ECl@ss 12.0 27272806 ETIM 5.0 EC001846 ETIM 6.0 EC001846 ETIM 7.0 EC001846 ETIM 8.0 EC001846 UNSPSC 16.0901 41111960