Key Commercial Data
Orderkey | 3009118 |
---|---|
Packing unit | 10 pc |
Catalog page | Page 257 (C-1-2017) |
GTIN | 4017918091644 |
Weight per Piece (excluding packing) | 113.400 g |
Custom tariff number | 85369010 |
Country of origin | CN (China) |
General
Number of levels | 1 |
---|---|
Number of connections | 2 |
Potentials | 1 |
Nominal cross section | 50 mm² |
Color | gray |
Insulating material | PA |
Flammability rating according to UL 94 | V0 |
Rated surge voltage | 8 kV |
Degree of pollution | 3 |
Overvoltage category | III |
Insulating material group | I |
Maximum power dissipation for nominal condition | 4.73 W |
Maximum load current | 150 A (with 50 mm² conductor cross section) |
Nominal current IN | 150 A |
Nominal voltage UN | 1000 V |
Open side panel | No |
Shock protection test specification | DIN EN 50274 (VDE 0660-514):2002-11 |
Back of the hand protection | guaranteed |
Finger protection | guaranteed |
Note regarding shock protection | Finger-safe protection is not guaranteed if bridges are positioned. |
Result of surge voltage test | Test passed |
Surge voltage test setpoint | 9.8 kV |
Result of power-frequency withstand voltage test | Test passed |
Power frequency withstand voltage setpoint | 2.2 kV |
Result of the test for mechanical stability of terminal points (5 x conductor connection) | Test passed |
Result of bending test | Test passed |
Bending test rotation speed | 10 rpm |
Bending test turns | 135 |
Bending test conductor cross section/weight | 25 mm² / 4.5 kg |
50 mm² / 9.5 kg | |
70 mm²/10.4 kg | |
Tensile test result | Test passed |
Conductor cross section tensile test | 25 mm² |
Tractive force setpoint | 135 N |
Conductor cross section tensile test | 50 mm² |
Tractive force setpoint | 236 N |
Conductor cross section tensile test | 70 mm² |
Tractive force setpoint | 285 N |
Result of tight fit on support | Test passed |
Tight fit on carrier | NS 32/NS 35 |
Setpoint | 10 N |
Result of voltage-drop test | Test passed |
Requirements, voltage drop | ≤ 3.2 mV |
Result of temperature-rise test | Test passed |
Short circuit stability result | Test passed |
Conductor cross section short circuit testing | 50 mm² |
Short-time current | 6 kA |
Result of thermal test | Test passed |
Proof of thermal characteristics (needle flame) effective duration | 30 s |
Relative insulation material temperature index (Elec., UL 746 B) | 130 °C |
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) | 130 °C |
Static insulating material application in cold | -60 °C |
Behavior in fire for rail vehicles (DIN 5510-2) | Test passed |
Flame test method (DIN EN 60695-11-10) | V0 |
Oxygen index (DIN EN ISO 4589-2) | >32 % |
NF F16-101, NF F10-102 Class I | 2 |
NF F16-101, NF F10-102 Class F | 2 |
Surface flammability NFPA 130 (ASTM E 162) | passed |
Specific optical density of smoke NFPA 130 (ASTM E 662) | passed |
Smoke gas toxicity NFPA 130 (SMP 800C) | passed |
Calorimetric heat release NFPA 130 (ASTM E 1354) | 28 MJ/kg |
Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 – HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 – HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 – HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 – HL 3 |
Connection data
Connection method | Screw connection |
---|---|
Screw thread | M6 |
Stripping length | 24 mm |
Tightening torque, min | 6 Nm |
Tightening torque max | 8 Nm |
Connection in acc. with standard | IEC 60947-7-1 |
Note | Note: Product releases, connection cross sections and notes on connecting aluminum cables can be found in the download area. |
Conductor cross section solid min. | 16 mm² |
Conductor cross section solid max. | 70 mm² |
Conductor cross section AWG min. | 6 |
Conductor cross section AWG max. | 2/0 |
Conductor cross section flexible min. | 25 mm² |
Conductor cross section flexible max. | 70 mm² |
Min. AWG conductor cross section, flexible | 3 |
Max. AWG conductor cross section, flexible | 2/0 |
Conductor cross section flexible, with ferrule without plastic sleeve min. | 25 mm² |
Conductor cross section flexible, with ferrule without plastic sleeve max. | 50 mm² |
Conductor cross section flexible, with ferrule with plastic sleeve min. | 25 mm² |
Conductor cross section flexible, with ferrule with plastic sleeve max. | 50 mm² |
2 conductors with same cross section, solid min. | 10 mm² |
2 conductors with same cross section, solid max. | 16 mm² |
2 conductors with same cross section, stranded min. | 10 mm² |
2 conductors with same cross section, stranded max. | 16 mm² |
2 conductors with same cross section, stranded, ferrules without plastic sleeve, min. | 10 mm² |
2 conductors with same cross section, stranded, ferrules without plastic sleeve, max. | 16 mm² |
Connection in acc. with standard | IEC/EN 60079-7 |
Conductor cross section solid min. | 16 mm² |
Conductor cross section solid max. | 50 mm² |
Conductor cross section AWG min. | 6 |
Conductor cross section AWG max. | 1/0 |
Conductor cross section flexible min. | 25 mm² |
Conductor cross section flexible max. | 50 mm² |
Internal cylindrical gage | B10 |
Standards and Regulations
Connection in acc. with standard | CSA |
---|---|
IEC 60947-7-1 | |
Flammability rating according to UL 94 | V0 |
Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 – HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 – HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 – HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 – HL 3 |
Environmental Product Compliance
China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
---|---|
No hazardous substances above threshold values |