Key Commercial Data
Orderkey | 1086510 |
---|---|
Packing unit | 1 pc |
Minimum order quantity | 5 pc |
Catalog page | Page 585 (C-1-2019) |
GTIN | 4055626879239 |
Weight per Piece (excluding packing) | 280.000 g |
Custom tariff number | 85369010 |
Country of origin | EE (Estonia) |
General
Note | Terminal block for aluminum and copper conductors (AL-CU) |
---|---|
Number of positions | 1 |
Number of levels | 1 |
Number of connections | 2 |
Potentials | 1 |
Nominal cross section | 240 mm² |
Color | yellow |
Insulating material | PA |
Flammability rating according to UL 94 | V0 |
Rated surge voltage | 8 kV |
Degree of pollution | 3 |
Overvoltage category | III |
Insulating material group | II |
Note | The following values apply to aluminum conductors |
Maximum load current | 380 A (with 240 mm² conductor cross section) |
Nominal current IN | 380 A |
Nominal voltage UN | 1000 V |
Note | The following values apply to copper wires |
Maximum load current | 415 A (with 240 mm² conductor cross section) |
Nominal current IN | 415 A |
Nominal voltage UN | 1000 V |
Open side panel | No |
Connection data
Note | Screws with hexagonal socket |
---|---|
Connection method | Screw connection |
Screw thread | M20 |
Stripping length | 43 mm |
Note | The following values apply to aluminum conductors |
Connection in acc. with standard | IEC 61238-1 |
Conductor cross section solid min. | 35 mm² |
Conductor cross section solid max. | 240 mm² |
Conductor cross section AWG min. | 3/0 |
Conductor cross section AWG max. | 500 |
Conductor cross section flexible min. | 35 mm² |
Conductor cross section flexible max. | 240 mm² |
Note | The values for aluminum conductors relate to multi-stranded conductors in accordance with EN 60228. Application notes on connecting aluminum conductors can be found in the download area. |
The following values apply to copper wires | |
Connection in acc. with standard | IEC 60947-7-1 |
Conductor cross section solid min. | 35 mm² |
Conductor cross section solid max. | 240 mm² |
Conductor cross section AWG min. | 3/0 |
Conductor cross section AWG max. | 500 |
Conductor cross section flexible min. | 35 mm² |
Conductor cross section flexible max. | 185 mm² |
Conductor cross section flexible, with ferrule without plastic sleeve min. | 35 mm² |
Conductor cross section flexible, with ferrule without plastic sleeve max. | 185 mm² |
Conductor cross section flexible, with ferrule with plastic sleeve min. | 35 mm² |
Conductor cross section flexible, with ferrule with plastic sleeve max. | 185 mm² |
2 conductors with same cross section, stranded min. | 35 mm² |
2 conductors with same cross section, stranded max. | 70 mm² |
Standards and Regulations
Connection in acc. with standard | IEC 61238-1 |
---|---|
IEC 60947-7-1 | |
Flammability rating according to UL 94 | V0 |
Environmental Product Compliance
China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
---|---|
No hazardous substances above threshold values |
Classifications
[email protected]
[email protected] 4.0 | 27141120 |
---|---|
[email protected] 4.1 | 27141120 |
[email protected] 5.0 | 27141120 |
[email protected] 5.1 | 27141100 |
[email protected] 6.0 | 27141100 |
[email protected] 7.0 | 27141120 |
[email protected] 8.0 | 27141120 |
[email protected] 9.0 | 27141120 |
ETIM
ETIM 2.0 | EC000897 |
---|---|
ETIM 3.0 | EC000897 |
ETIM 4.0 | EC000897 |
ETIM 5.0 | EC000897 |
ETIM 6.0 | EC000897 |
ETIM 7.0 | EC000897 |