Model Sensor without system plug Application Indoor Protective field range 3 m Warning field range 10 m Distance measuring range 40 m Number of simultaneously monitored fields ≤ 8 1) Number of fields 128 Number of monitoring cases 128 Scanning angle 275° Resolution (can be configured) 20 mm
30 mm
40 mm
50 mm
60 mm
70 mm
150 mm
200 mm
Angular resolution 0.17° Response time ≥ 70 ms Protective field supplement 65 mm - 1) Protection, warning or contour detection fields.
-
Safety-related parameters
Type Type 3 (IEC 61496) Safety integrity level SIL2 (IEC 61508) Category Category 3 (EN ISO 13849) Performance level PL d (EN ISO 13849) PFHD (mean probability of a dangerous failure per hour) 8.0 x 10-8 TM (mission time) 20 years (EN ISO 13849) Safe state in the event of a fault The safety outputs via the network are logic 0.
-
Functions
Restart interlock ✔ External device monitoring (EDM) ✔ Multiple sampling ✔ Monitoring case switching ✔ Simultaneous monitoring ✔ Static protective field switching ✔ Dynamic protective field switching ✔ Safe contour detection ✔ Contour as a reference ✔ Integrated configuration memory ✔ Measured data output Via Ethernet Safe SICK device communication via EFI-pro ✔
-
Interfaces
Connection type Depending on system plug Outputs OSSD pairs 0 Safety outputs via network 8 Configuration method PC with Safety Designer (Configuration and Diagnostic Software) Configuration and diagnostics interface USB 2.0, micro USB Data interface Services EtherNet/IP™ CIP Safety™ CoLa 2 (configuration and diagnostics using Safety Designer) Data output DHCP SNMP SNTP (client and server) Fieldbus, industrial network EFI-pro RPI (requested packet interval) 5 ms … 1,000 ms, multiple of 5 ms Display elements Graphic color display, LEDs
-
Electrical data
Protection class III (EN 61140) Supply voltage Vs 24 V DC (16.8 V DC … 30 V DC) Power consumption 3.9 W (without output load)
-
Mechanical data
Dimensions (W x H x D) 106.6 mm x 80 mm x 117.5 mm (including system plug) Weight 0.67 kg Housing material Aluminum Housing color RAL 1021 (yellow), RAL 9005 (black) Optics cover material Polycarbonate
-
Ambient data
Enclosure rating IP65 (IEC 60529) Ambient light immunity ≤ 40 klx (IEC 61496-3) 1) Ambient operating temperature –10 °C … +50 °C Storage temperature –25 °C … +70 °C Vibration resistance IEC 60068-2-6, IEC 60068-2-64, IEC 60721-3-5, IEC TR 60721-4-5, IEC 61496-3 Class 5M1 (IEC 60721-3-5) Shock resistance IEC 60068-2-27, IEC 60721-3-5, IEC TR 60721-4-5, IEC 61496-3 Class 5M1 (IEC 60721-3-5) Continuous shock 50 m/s², 11 ms 100 m/s², 16 ms EMC IEC 61496-1
IEC 61000-6-2
IEC 61000-6-3
- 1) Typical ambient light immunity, for ambient light sources directly in the scan plane in accordance with IEC 61496-3: ≤ 3 klx.
-
Other information
Type of light Pulsed laser diode Wave length 905 nm Detectable remission factor 1.8% to several 1000% Laser class 1 (21 CFR 1040.10 and 1040.11, IEC 60825-1)
-
Classifications
eCl@ss 5.0 27272705 eCl@ss 5.1.4 27272705 eCl@ss 6.0 27272705 eCl@ss 6.2 27272705 eCl@ss 7.0 27272705 eCl@ss 8.0 27272705 eCl@ss 8.1 27272705 eCl@ss 9.0 27272705 eCl@ss 10.0 27272705 eCl@ss 11.0 27272705 eCl@ss 12.0 27272705 ETIM 5.0 EC002550 ETIM 6.0 EC002550 ETIM 7.0 EC002550 ETIM 8.0 EC002550 UNSPSC 16.0901 39121528