Features
System part Sensor Measurement principle HDDM Application Indoor Light source Infrared (850 nm) Laser class 1 (IEC 60825-1:2014, EN 60825-1:2014) Aperture angle Horizontal 270° Scanning frequency 15 Hz Angular resolution 0.33° Scan field flatness ± 1.5° Working range 0.05 m … 25 m (> 90% remission) Safety-related working range 0.05 m … 5 m (At 5% remission) Blind zone 0 m … 0.05 m Scanning range At 10% remission 8 m
-
Mechanics/electronics
Connection type 1 x “Ethernet” connection, 4-pin M12 female connector
1 x connection “Power”, 12-pin, M12 male connector
1 x Micro USB female connector, type B
Supply voltage 9 V DC … 28 V DC Power consumption Typ. 4 W, 16 W with 4 max. loaded digital outputs Output current ≤ 100 mA Housing color Yellow Enclosure rating IP67, applies only when the plastic cover of the “Aux interface” is closed (IEC 60529:1989+AMD1:1999+AMD2:2013) Protection class III (IEC 61140:2016-1) Weight 250 g, without connecting cables Dimensions (L x W x H) 60 mm x 60 mm x 86 mm
-
Safety-related parameters
Category B (EN ISO 13849-1:2015) Performance level PL b (EN ISO 13849-1:2015) Performance class SRS/SRSS B (IEC TS 62998-1:2019) TM (mission time) 20 years (EN ISO 13849-1:2015) Conformities EN ISO 13849-1:2015, ANSI/ITSDF B56.5:2012, IEC TS 62998-1:2019, EN ISO 13482:2014, EN ISO 13855:2010 MTBF > 100 years MTTFD 100 years, at 25 °C ambient temperature (EN ISO 13849-1:2015)
-
Performance
Response time 1 scan, typ. 67 ms
2 scans, ≤ 134 ms 1)
Detectable object shape Almost any Systematic error ± 60 mm 2) Statistical error < 20 mm 2)
< 10 mm 3)
Safety-related statistical error < 60 mm (4,4 σ) Integrated application Protective field evaluation with flexible fields
Output of measurement data
Protective field tolerance 100 mm, 0.66° (DIN CLC/TS 62046:2009, 5% remission) Number of field sets 16 field triples (48 protective fields) Simultaneous evaluation cases 3 simultaneous protective fields (per field set) - 1) At +45° to +225° of the working range; max. 150 ms at –45° to +45° of the working range.
- 2) Typical value at 90% remission up to maximum scanning range; real value depends on ambient conditions.
- 3) Typical value at 10% remission up to 6 m scanning range; real value depends on ambient conditions.
-
Interfaces
Ethernet ✔ , TCP/IP USB ✔ Remark Micro USB Function Parameterization Digital inputs 4 (PNP, for field set switching) Digital outputs 3 (PNP, to display a protective field violation, additional 1 x “Device Ready”) Delay time 67 ms … 30,000 ms (configurable) Dwell time 67 ms … 600,052 ms (configurable) Optical indicators 2 LEDs (ON, “device ready”)
-
Ambient data
Object remission ≥ 5 % (reflectors) 1) Electromagnetic compatibility (EMC) Emitted radiation Residential area (IEC 61000-6-3:2006+AMD1:2010) Electromagnetic immunity Industrial environment (IEC 61000-6-2:2005) Vibration resistance Sine resonance scan 10 Hz … 1,000 Hz 2) Sine test 10 Hz … 500 Hz, 5 g, 10 frequency cycles 2) Noise test 10 Hz … 250 Hz, 4.24 g RMS, 5 h 3) Shock resistance 50 g, 11 ms, ± 3 single shocks/axis 4)
25 g, 6 ms, ± 1,000 continuous shocks/axis 4)
50 g, 3 ms, ± 5,000 continuous shocks/axis 4)
Ambient operating temperature –25 °C … +50 °C 5) Storage temperature –40 °C … +75 °C 5) Switch-on temperature –10 °C … +50 °C Temperature change –25 °C … +50 °C, 10 cycles 6) Damp heat +25 °C … +55 °C, 95 % RH, 6 cycles 7) Permissible relative humidity Operation < 80 %, Non-condensing (EN 60068-2-30:2005) Storage ≤ 90 %, Non-condensing (EN 60068-2-30:2005) Ambient light immunity 80,000 lx
3,000 lx, With direct light
- 1) When using reflectors, observe notes in the operating instructions.
- 2) IEC 60068-2-6:2007.
- 3) IEC 60068-2-64:2008.
- 4) IEC 60068-2-27:2008.
- 5) IEC 60068-2-14:2009.
- 6) EN 60068-2-14:2009.
- 7) EN 60068-2-30:2005.
-
General notes
Note on use The TiM771S is a safety-related sensor that is suitable for use in the following applications: Hazardous area, hazardous point, and access protection as well as mobile hazardous area protection (protection of automated guided vehicles and mobile platforms). The sensor must only ever be used within the limits of the prescribed and specified technical data and operating conditions.
-
Classifications
eCl@ss 5.0 27270990 eCl@ss 5.1.4 27270990 eCl@ss 6.0 27270913 eCl@ss 6.2 27270913 eCl@ss 7.0 27270913 eCl@ss 8.0 27270913 eCl@ss 8.1 27270913 eCl@ss 9.0 27270913 eCl@ss 10.0 27270913 eCl@ss 11.0 27270913 eCl@ss 12.0 27270913 ETIM 5.0 EC002550 ETIM 6.0 EC002550 ETIM 7.0 EC002550 ETIM 8.0 EC002550 UNSPSC 16.0901 41111615