Features
Model Sensor including system plug (pre-mounted on the underside) Application Indoor Protective field range 4 m Warning field range 40 m Number of simultaneously monitored fields ≤ 8 1) Number of fields 128 Number of monitoring cases 128 Scanning angle 275° Resolution (can be configured) 30 mm
40 mm
50 mm
70 mm
150 mm
200 mm
Angular resolution 0.39° Response time ≥ 70 ms Protective field supplement 65 mm - 1) Protection, warning or contour detection fields.
-
Safety-related parameters
Type Type 3 (IEC 61496) Safety integrity level SIL2 (IEC 61508) Category Category 3 (EN ISO 13849) Performance level PL d (EN ISO 13849) PFHD (mean probability of a dangerous failure per hour) 8.0 x 10-8 TM (mission time) 20 years (EN ISO 13849) Safe state in the event of a fault At least one OSSD is in the OFF state.
The safety outputs via the network are logic 0.
-
Functions
Restart interlock ✔ External device monitoring (EDM) ✔ Multiple sampling ✔ Monitoring case switching ✔ Simultaneous monitoring ✔ Static protective field switching ✔ Safe contour detection ✔ Contour as a reference ✔ Integrated configuration memory ✔ Measured data output Via Ethernet Safe SICK device communication via EFI-pro ✔
-
Interfaces
Connection type Voltage supply 1 x male connector, M12, 4-pin, A-coded Local inputs and outputs (I/O) 2 x female connector, M12, 17-pin, A-coded Dynamic switching signals 2 x female connector, M12, 8-pin, A-coded Fieldbus, industrial network 2 x M12 female connectors, 4-pin, D-coded Outputs OSSD pairs 4 Safety outputs via network 8 Universal outputs 4 1) Inputs Universal inputs ≤ 16 1) Dynamic switching signals 2 Static control inputs ≤ 8 Configuration method PC with Safety Designer (Configuration and Diagnostic Software) Configuration and diagnostics interface USB 2.0, Mini-USB, Ethernet Data interface Services EtherNet/IP™ CIP Safety™ CoLa 2 (configuration and diagnostics using Safety Designer) Data output DHCP SNMP SNTP (client and server) Fieldbus, industrial network EFI-pro RPI (requested packet interval) 5 ms … 1,000 ms, multiple of 5 ms Display elements Graphic color display, LEDs - 1) Freely configurable.
-
Electrical data
Protection class III (EN 61140) Supply voltage Vs 24 V DC (16.8 V DC … 30 V DC) Power consumption 8.1 W (without output load)
-
Mechanical data
Dimensions (W x H x D) 112 mm x 163 mm x 111.1 mm Weight 1.6 kg Housing material Aluminum Housing color RAL 1021 (yellow), RAL 9005 (black) Optics cover material Polycarbonate Optics cover surface finish Outside with scratch-resistant coating
-
Ambient data
Enclosure rating IP65 (IEC 60529) Ambient light immunity ≤ 3,000 lx (IEC 61496-3) Ambient operating temperature –10 °C … +50 °C Storage temperature –25 °C … +70 °C Vibration resistance IEC 60068-2-6, IEC 60068-2-64, IEC 60721-3-5, IEC TR 60721-4-3, IEC 61496-1, IEC 61496-3 Class 5M1 (IEC 60721-3-5) 3M4 (IEC TR 60721-4-3) Shock resistance IEC 60068-2-27, IEC 60721-3-5, IEC TR 60721-4-3, IEC 61496-1, IEC 61496-3 Class 5M1 (IEC 60721-3-5) 3M4 (IEC TR 60721-4-3) Continuous shock 100 m/s², 16 ms 150 m/s², 6 ms EMC IEC 61496-1
IEC 61000-6-2
IEC 61000-6-4
-
Other information
Type of light Pulsed laser diode Wave length 845 nm Detectable remission factor 1.8% to several 1000% Laser class 1M (21 CFR 1040.10 and 1040.11, IEC 60825-1)
-
Classifications
eCl@ss 5.0 27272705 eCl@ss 5.1.4 27272705 eCl@ss 6.0 27272705 eCl@ss 6.2 27272705 eCl@ss 7.0 27272705 eCl@ss 8.0 27272705 eCl@ss 8.1 27272705 eCl@ss 9.0 27272705 eCl@ss 10.0 27272705 eCl@ss 11.0 27272705 eCl@ss 12.0 27272705 ETIM 5.0 EC002550 ETIM 6.0 EC002550 ETIM 7.0 EC002550 ETIM 8.0 EC002550 UNSPSC 16.0901 39121528