Features
Model Sensor without system plug Application Indoor Protective field range 9 m Warning field range 64 m Number of simultaneously monitored fields ≤ 4 1) Number of fields 128 Number of monitoring cases 128 Scanning angle 275° Resolution (can be configured) 30 mm
40 mm
50 mm
60 mm
70 mm
150 mm
200 mm
Angular resolution 0.1° Response time ≥ 115 ms Protective field supplement 100 mm - 1) Protection, warning or contour detection fields.
-
Safety-related parameters
Type Type 3 (IEC 61496) Safety integrity level SIL2 (IEC 61508) Category Category 3 (EN ISO 13849) Performance level PL d (EN ISO 13849) PFHD (mean probability of a dangerous failure per hour) 8.0 x 10-8 TM (mission time) 20 years (EN ISO 13849) Safe state in the event of a fault The safety outputs via the network are logic 0.
-
Functions
Restart interlock ✔ Multiple sampling ✔ Monitoring case switching ✔ Simultaneous monitoring ✔ Static protective field switching ✔ Safe contour detection ✔ Contour as a reference ✔ Integrated configuration memory ✔ Measured data output Via Ethernet
-
Interfaces
Connection type Voltage supply 1 x male connector, M12, 4-pin, A-coded Data interface 1 x M12 female connectors, 4-pin, D-coded Fieldbus, industrial network 2 x M12 female connectors, 4-pin, D-coded Outputs OSSD pairs 0 Safety outputs via network 8 Configuration method PC with Safety Designer (Configuration and Diagnostic Software) Configuration and diagnostics interface USB 2.0, Mini-USB Data interface Type of data interface Ethernet for data output, configuration and diagnostics (XF1, XF3) Port properties 100Base-TX Auto-negotiation Auto-crossover (MDIX) Auto-polarity Services Configuration and diagnostics using Safety Designer Data output Time synchronization via SNTP Fieldbus, industrial network EtherCAT® Protocol FSoE (Safety over EtherCAT®) Cycle time ≥ 500 µs Port properties XF1: EtherCAT IN XF2: EtherCAT OUT Diagnostics Process data objects (PDOs) Service data objects (SDOs) Additional services Ethernet over EtherCAT (EoE) for configuration and diagnostics using Safety Designer CAN application protocol over EtherCAT (CoE) Display elements Graphic color display, LEDs
-
Electrical data
Protection class III (EN 61140) Supply voltage Vs 24 V DC (16.8 V DC … 30 V DC) Power consumption 7 W (without output load)
-
Mechanical data
Dimensions (W x H x D) 112 mm x 150.8 mm x 111.1 mm Housing material Aluminum Housing color RAL 1021 (yellow), RAL 9005 (black) Optics cover material Polycarbonate Optics cover surface finish Outside with scratch-resistant coating
-
Ambient data
Enclosure rating IP65 (IEC 60529) Ambient light immunity ≤ 3,000 lx (IEC 61496-3) Ambient operating temperature –10 °C … +50 °C Storage temperature –25 °C … +70 °C Vibration resistance IEC 60068-2-6, IEC 60068-2-64, IEC 60721-3-5, IEC TR 60721-4-3, IEC 61496-1, IEC 61496-3 Class 5M1 (IEC 60721-3-5) 3M4 (IEC TR 60721-4-3) Shock resistance IEC 60068-2-27, IEC 60721-3-5, IEC TR 60721-4-3, IEC 61496-1, IEC 61496-3 Class 5M1 (IEC 60721-3-5) 3M4 (IEC TR 60721-4-3) Continuous shock 100 m/s², 16 ms 150 m/s², 6 ms EMC IEC 61496-1
IEC 61000-6-2
IEC 61000-6-4
-
Other information
Type of light Pulsed laser diode Wave length 845 nm Detectable remission factor 1.8% to several 1000% Laser class 1M (21 CFR 1040.10 and 1040.11, IEC 60825-1)
-
Classifications
eCl@ss 5.0 27272705 eCl@ss 5.1.4 27272705 eCl@ss 6.0 27272705 eCl@ss 6.2 27272705 eCl@ss 7.0 27272705 eCl@ss 8.0 27272705 eCl@ss 8.1 27272705 eCl@ss 9.0 27272705 eCl@ss 10.0 27272705 eCl@ss 11.0 27272705 eCl@ss 12.0 27272705 ETIM 5.0 EC002550 ETIM 6.0 EC002550 ETIM 7.0 EC002550 ETIM 8.0 EC002550 UNSPSC 16.0901 39121528