Mechanics/electronics
Supply voltage Vs DC 19.2 V … 26.4 V 1) Ripple ≤ 5 Vpp 2) Power consumption ≤ 1.7 W 3) Initialization time ≤ 500 ms Warm-up time ≤ 20 min Housing material Plastic (ABS/PC) Window material Plastic (PMMA) Connection type Male connector, M12, 5-pin Indication LEDs Weight 65 g Dimensions (W x H x D) 32 mm x 58.67 mm x 42.7 mm Enclosure rating IP67 Protection class III Electrical safety IEC 61010-1 (ed. 3) - 1) Limit values, reverse-polarity protected, operation in short-circuit protected network: max. 8 A.
- 2) May not fall short of or exceed VS tolerances.
- 3) Without load, at +20 °C.
-
Safety-related parameters
Category B (EN ISO 13849-1:2015) Performance level PL b (EN ISO 13849-1:2015) Performance class SRS/SRSS B (IEC TS 62998-1:2019) TM (mission time) 20 years (EN ISO 13849-1:2015) 1) Max. cumulative downtime per year < 5 min (IEC TS 62998-1) Conformities EN ISO 13849-1:2015, IEC TS 62998-1:2019, EN ISO 13482:2014, ANSI/ITSDF B56.5:2012 - 1) 10 years at 50 °C ambient temperature.
-
Performance
Safety-related measuring range 50 mm … 8,500 mm, 90 % remission 1)
50 mm … 4,500 mm, 20% remission
50 mm … 3,000 mm, 10% remission
50 mm … 2,000 mm, 6 % remission
Target Natural objects Resolution 1 mm Systematic error < 25 mm 2) Statistical error < 25 mm 2) 3) Response time 15 ms … 50 ms 4) 5) Light source Laser, red 6)
visible red lightLaser class 2 (IEC 60825-1:2014, EN 60825-1:2014) Typ. light spot size (distance) 15 mm x 15 mm (at 2 m) Additional function Adjustable speed: slow and medium, teach-in of analog output and invertible analog output, Configurable Q2 output: current output / digital output, Switching mode: Distance to Object (DtO) / switching window / object between sensor and background (ObSB), teach-in of digital output, Multifunctional input: laser off / deactivated - 1) With the Slow speed setting. No objects will be detected from the measurement origin to a distance of 50 mm.
- 2) 6 % … 90 % remission.
- 3) Corresponds to 4.4 σ.
- 4) Depending on the configured speed and interface.
- 5) Lateral entry of the object into the measuring range.
- 6) Wavelength: 658 nm; max. output: 250 mW; pulse duration: 4 ns; duty cycle: 1/250.
-
Interfaces
IO-Link ✔ , V1.1 Function Process data Data transmission rate 38,4 kbit/s (COM2) Digital output Number 1 … 2 1) 2) Type Push-pull: PNP/NPN Function Configurable Q2 output: analog output / digital output Maximum output current IA ≤ 100 mA Analog output Number 1 Type Current output Current 4 mA … 20 mA, ≤ 450 Ω Resolution 12 bit Multifunctional input (MF) 1 x 3) Hysteresis 10 mm
25 mm
50 mm
Interface for parametrization SOPAS ET 4) - 1) Output Q short-circuit protected.
- 2) Voltage drop < 3 V.
- 3) Response time ≤ 60 ms.
- 4) Additional SiLink2 Master accessory required.
-
Ambient data
Electromagnetic compatibility (EMC) EN 61000-6-3
EN 61000-6-2
Ambient temperature, operation –25 °C … +50 °C, Uv ≤ 24 V Ambient temperature, storage –40 °C … +75 °C Max. rel. humidity (not condensing) ≤ 95 % Temperature drift 0.5 mm/K Typ. Ambient light immunity Direct exposure: 3,000 lx
Indirect exposure: 40,000 lx
Vibration resistance EN 60068-2-6, EN 60068-2-64 Shock resistance EN 60068-2-27
-
Classifications
eCl@ss 5.0 27270801 eCl@ss 5.1.4 27270801 eCl@ss 6.0 27270801 eCl@ss 6.2 27270801 eCl@ss 7.0 27270801 eCl@ss 8.0 27270801 eCl@ss 8.1 27270801 eCl@ss 9.0 27270801 eCl@ss 10.0 27270801 eCl@ss 11.0 27270801 eCl@ss 12.0 27270916 ETIM 5.0 EC001825 ETIM 6.0 EC001825 ETIM 7.0 EC001825 ETIM 8.0 EC001825 UNSPSC 16.0901 41111613