Technical features
Detection properties
Nominal sensing distance |
1600 | 2600mm |
|
Sensitivity adjustment |
Teach-in |
Application
Function Principle |
Optic fiber amplifier |
|
Description |
Slim case with display |
|
Optic position |
axial |
|
Functions |
Optic fiber amplifier |
Outputs
Output type |
NPN, 4…20mA |
|
Switching frequency |
1 Khz(HIGH SPEED) 500 Hz (FAST) 250 Hz (Standard) 62,5 Hz(Long Range) 20Hz (Extra long Range) |
|
Response time |
0,5 |
Electrical data
Operating Voltage |
10…30VDC |
|
No-Load supply current |
≤ 40mA (standard display mode), ≤ 30mA (ECO displsy mode) |
|
Load current |
≤100mA |
|
Output voltage drop |
≤1,5V@Iload=100mA |
|
LED indicators |
Yellow (output state) Red (Signal level -4 digits) Green (Threshold – 4 digits) |
|
Short-circuit protection |
YES |
|
Reverse Polarity Protection |
Yes |
|
Emission |
LED Red (660nm) |
|
Interference to external light |
according to EN 60947-5-2 : 2020 |
|
Impulsive Overvoltage Protection |
Yes |
|
Insulation resistance |
>20 MΩ 500 Vdc, between electronics and housing |
|
Contact resistance |
500 Vac 1 min., between electronics and housing |
Mechanical data
Dimensions |
10x32x80 |
|
Housing Material |
ABS(Housing), PMMA (Optics) |
|
Connections |
M8 plug 4pin |
|
Active Head Material |
PMMA |
|
Storage temperature |
– 25°C…+85°C |
|
Material |
Plastic ABS / PC |
|
Diameter/Dimension |
Cubic |
Test/Approvals
Approvals |
CE cULus |
|
Shocks and vibrations |
0.5 mm amplitude, 10 … 55 Hz frequency, for every axis (EN60068-2-6) |
Generical Data
Dimensions |
10x32x80 |
|
Operating Temperature |
– 10°C…+ 55°C |
|
Mechanical Protection |
IP67 with cover |
S70-5-E3-NI