Technical features
Detection properties
Nominal sensing distance |
300mm |
|
Spot dimension |
2mm |
|
Resolution |
0.01…0.33 mm |
|
Sensitivity adjustment |
Teach-in |
|
Minimum sensing distance (blind zone) |
50 |
|
Linearity error |
±0.03…±1.0 mm |
Application
Function Principle |
Distance sensor – Micrometric |
|
Description |
Large case vertical mount |
|
Optic position |
Radial 90° |
|
Functions |
Distance sensor – Micrometric |
Outputs
Output type |
0…10V Analog Current Output : load resistance (analog I) < (+Vs – 6 V) / 0,02 (-I) Analog Voltage Output : load resistance > 100 kOhm (-V |
|
Output Function |
Analog Current Output : load resistance (analog I) < (+Vs – 6 V) / 0,02 (-I) Analog Voltage Output : load resistance > 100 kOhm (-V |
|
Response time |
1 |
Electrical data
Operating Voltage |
12..28VDC±10% |
|
No-Load supply current |
≤100mA |
|
LED indicators |
Red LED Alarm/Soiled lens indicator Green LED Power indicator Push Button Teach in |
|
Short-circuit protection |
YES |
|
Reverse Polarity Protection |
Yes |
|
Emission |
LASER Red |
|
Interference to external light |
according to EN 60947-5-2 : 2020 |
|
Impulsive Overvoltage Protection |
Yes |
|
Optical power class |
CLASS 2 According to IEC 60825-1 (2014) |
|
Insulation resistance |
>20 MΩ 500 Vdc, between electronics and housing |
|
Contact resistance |
500 Vac 1 min., between electronics and housing |
Mechanical data
Dimensions |
20x65x50 |
|
Housing Material |
Metal die-cast Zinc / Glass |
|
Connections |
M12 plug |
|
Active Head Material |
PMMA |
|
Storage temperature |
– 25°C…+70°C |
|
Material | ||
Diameter/Dimension |
Cubic |
Test/Approvals
Approvals |
CE cULus |
|
Shocks and vibrations |
0.5 mm amplitude, 10 … 55 Hz frequency, for every axis (EN60068-2-6) |
Generical Data
Dimensions |
20x65x50 |
|
Mechanical Protection |
IP67 |
S67-MH-5-Y03-V