Key Commercial Data
| Orderkey | 3049835 |
|---|---|
| Packing unit | 50 pc |
| Minimum order quantity | 50 pc |
| Note | Made to Order (non-returnable) |
| Catalog page | Page 377 (C-1-2017) |
| GTIN | 4046356425131 |
| Weight per Piece (excluding packing) | 20.890 g |
| Custom tariff number | 85369010 |
| Country of origin | CN (China) |
General
| Note | Note: the BE-RT… path extension is to be used for non-insulated cable lugs (see accessories). |
|---|---|
| Number of levels | 1 |
| Number of connections | 2 |
| Potentials | 1 |
| Nominal cross section | 2.5 mm² |
| Color | blue |
| Insulating material | PA |
| Flammability rating according to UL 94 | V0 |
| Rated surge voltage | 8 kV |
| Degree of pollution | 3 |
| Overvoltage category | III |
| Insulating material group | I |
| Maximum power dissipation for nominal condition | 0.77 W |
| Maximum load current | 24 A (with a 2.5 mm² conductor cross section) |
| Nominal current IN | 24 A |
| Nominal voltage UN | 1000 V |
| Open side panel | Yes |
| Result of surge voltage test | Test passed |
| Surge voltage test setpoint | 9.8 kV |
| Result of power-frequency withstand voltage test | Test passed |
| Power frequency withstand voltage setpoint | 2.2 kV |
| Result of the test for mechanical stability of terminal points (5 x conductor connection) | Test passed |
| Result of tight fit on support | Test passed |
| Tight fit on carrier | NS 35 |
| Setpoint | 1 N |
| Result of voltage-drop test | Test passed |
| Requirements, voltage drop | ≤ 3.2 mV |
| Result of temperature-rise test | Test passed |
| Short circuit stability result | Test passed |
| Conductor cross section short circuit testing | 2.5 mm² |
| Short-time current | 0.3 kA |
| Result of thermal test | Test passed |
| Proof of thermal characteristics (needle flame) effective duration | 30 s |
Dimensions
| Width | 12.3 mm |
|---|---|
| End cover width | 2.2 mm |
| Length | 66 mm |
| Height NS 35/7,5 | 51 mm |
| Height NS 35/15 | 58.5 mm |
Connection data
| Note | Connection bolts |
|---|---|
| Connection method | Bolt connection |
| Screw thread | M3 |
| Tightening torque, min | 0.6 Nm |
| Tightening torque max | 0.8 Nm |
| Conductor cross section solid min. | 0.5 mm² |
| Conductor cross section solid max. | 2.5 mm² |
| Conductor cross section flexible min. | 0.1 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Min. AWG conductor cross section, flexible | 26 |
| Max. AWG conductor cross section, flexible | 14 |
| Conductor cross section flexible, with ferrule with plastic sleeve min. | 0.1 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve max. | 2.5 mm² |
| Cable lug connection according to standard | DIN 46234 |
| Min. cross section for cable lug connection | 0.5 mm² |
| Max. cross section for cable lug connection | 2.5 mm² |
| Hole diameter, min. | 3.2 mm |
| Cable lug width, max. | 6 mm |
| Bolt diameter | 3 mm |
| Cable lug connection according to standard | DIN 46237 |
| Min. cross section for cable lug connection | 1 mm² |
| Max. cross section for cable lug connection | 2.5 mm² |
| Hole diameter, min. | 3.2 mm |
| Cable lug width, max. | 6 mm |
| Bolt diameter | 3 mm |
Environmental Product Compliance
| China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
|---|---|
| No hazardous substances above threshold values |