Key Commercial Data
Orderkey | 2909055 |
---|---|
Packing unit | 1 |
Catalog page | Page 312 (C-5-2019) |
GTIN | 4055626358789 |
Custom tariff number | 85364900 |
Note
Note | The outputs are not suitable for switching different outer conductors. |
---|---|
Do not use to separate SELV / PELV circuits from other circuits, because safe isolation is not guaranteed. |
Ambient conditions
Ambient temperature (operation) | -40 °C … 70 °C |
---|---|
Ambient temperature (storage/transport) | -40 °C … 85 °C |
Maximum altitude | ≤ 2000 m |
Degree of protection | RT I |
≥ IP54 (Installation location) |
Coil side
Nominal input voltage UN | 220 V DC |
---|---|
Typical input current at UN | 6 mA |
Non-operate voltage | < 132 V DC |
Safe operate voltage | > 176 V DC |
Typical response time | 20 ms |
Typical release time | 15 ms |
Coil resistance | 37000 Ω ±10 % |
Power dissipation for nominal condition | 1.34 W |
Contact side
Contact type | 3 PDTs |
---|---|
Type of switch contact | Single contact |
Contact material | AgNi |
Maximum switching voltage | 440 V AC |
250 V DC | |
Minimum switching voltage | 10 V (At 24 mA) |
Min. switching current | 10 mA (at 24 V) |
Maximum inrush current | 50 A (20 ms, N/O contacts) |
Limiting continuous current | 16 A |
Interrupting rating (ohmic load) max. | 384 W (at 24 V DC) |
124 W (at 48 V DC) | |
108 W (at 60 V DC) | |
52 W (at 110 V DC) | |
70 W (at 220 V DC) | |
4000 VA (for 250 V AC) | |
4000 VA (at 440 V AC) | |
3-phase motor load | 1500 W (at 400 V, AC3) |
Motor load according to UL 508 | 1/3 HP, 120 V AC (single-phase AC motor) |
1/2 HP, 240 V AC (single-phase AC motor) | |
1/2 HP, 240 V AC (three-phase induction motor) |
General
Test voltage relay winding/relay contact | 2.5 kVrms(50 Hz, 1 min.) |
---|---|
Test voltage PDT/PDT | 2.5 kVrms(50 Hz, 1 min.) |
Operating mode | 100% operating factor |
Mechanical service life | approx. 107cycles |
Service life, electrical | see diagram |
Mounting position | any |
Standards and Regulations
Standards/regulations | IEC 60664 |
---|---|
IEC 61810 | |
Rated insulation voltage | 250 V AC |
Rated surge voltage | 4 kV |
Insulation | Basic insulation |
Pollution degree | 3 |
Overvoltage category | III |
Environmental Product Compliance
China RoHS | Environmentally Friendly Use Period = 50 |
---|---|
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer’s declaration” |
Classifications
[email protected]
[email protected] 5.0 | 27371601 |
---|---|
[email protected] 5.1 | 27371601 |
[email protected] 6.0 | 27371601 |
[email protected] 7.0 | 27371601 |
[email protected] 8.0 | 27371601 |
[email protected] 9.0 | 27371601 |
ETIM
ETIM 2.0 | EC001437 |
---|---|
ETIM 3.0 | EC001437 |
ETIM 4.0 | EC001437 |
ETIM 5.0 | EC001437 |
ETIM 6.0 | EC001437 |
ETIM 7.0 | EC001437 |