Features
Functional principle Photoelectric retro-reflective sensor Functional principle detail Autocollimation, Reflex Array Dimensions (W x H x D) 24.6 mm x 82.5 mm x 53.3 mm Housing design (light emission) Rectangular Minimum object size 3 mm, position-independent detection within the light array (factory setting), adjustable via IO-Link incl. adjustable conveyor belt suppression
5 mm, position-independent detection within the light array, adjustable via IO-Link incl. adjustable conveyor belt suppression
10 mm, position-independent detection within the light array, adjustable via IO-Link incl. adjustable conveyor belt suppression
Detection height 55 mm Sensing range max. 0 m … 2 m 1) 2)
0 m … 3 m 1) 3)
0 m … 4.5 m 1) 4)
Distance of the sensor to reflector ≥ 0 m Conveyor belt suppression Manual, via IO-Link Type of light Visible red light Light source PinPoint LED 5) Light spot size (distance) 55 mm x 9 mm (1 m) Wave length 635 nm Adjustment BluePilot: Teach-in
IO-Link
Pin 2 configuration External Input (test), Teach-in, switching signal AutoAdapt ✔ Special applications Detecting objects with position tolerances, Detecting perforated objects, Detecting uneven, shiny objects, Detecting transparent objects, Detecting flat objects - 1) Reflector PL80A.
- 2) At minimum object size 3 mm.
- 3) At minimum object size 5 mm.
- 4) At minimum object size 10 mm.
- 5) Average service life: 100,000 h at TU = +25 °C.
-
Mechanics/electronics
Supply voltage 10 V DC … 30 V DC 1) Ripple < 5 Vpp Current consumption 25 mA 2)
40 mA 3)
Switching output Push-pull: PNP/NPN Output: QL1 / C Switching output or IO-Link mode Output function Factory setting: Pin 2 / white (MF): NPN normally closed (light switching), PNP normally open (dark switching), Pin 4 / black (QL1 / C): NPN normally open (dark switching), PNP normally closed (light switching), IO-Link Switching mode Light/dark switching Switching mode selector Via IO-Link Signal voltage PNP HIGH/LOW Approx. VS – 2.5 V / 0 V Signal voltage NPN HIGH/LOW Approx. VS / < 2.5 V Output current Imax. ≤ 100 mA Response time ≤ 3 ms 4) Switching frequency 170 Hz 5) Connection type Male connector M12, 4-pin Circuit protection A 6)
B 7)
C 8)
D 9)
Protection class III Weight 80 g Housing material Plastic, VISTAL® Optics material Plastic, PMMA Enclosure rating IP66
IP67
Ambient operating temperature –40 °C … +60 °C 10) 11) Ambient temperature, storage –40 °C … +75 °C UL File No. NRKH.E181493 & NRKH7.E181493 - 1) Limit values.
- 2) 16 V DC … 30 V DC, without load.
- 3) 10 V DC … 16 V DC, without load.
- 4) Signal transit time with resistive load in switching mode. Different values possible in COM2 mode.
- 5) With light/dark ratio 1:1 in switching mode. Different values possible in IO-Link mode.
- 6) A = VS connections reverse-polarity protected.
- 7) B = inputs and output reverse-polarity protected.
- 8) C = interference suppression.
- 9) D = outputs overcurrent and short-circuit protected.
- 10) Avoid condensation on the front screen of the sensor and on the reflector.
- 11) Allowed temperature change after Teach +/- 20 K.
-
Safety-related parameters
MTTFD 709 years DCavg 0 %
-
Communication interface
Communication interface IO-Link V1.1 Communication Interface detail COM2 (38,4 kBaud) Cycle time 2.3 ms Process data length 16 Bit Process data structure Bit 0 = switching signal QL1
Bit 1 = switching signal QL2
Bit 2 … 15 = empty
VendorID 26 DeviceID HEX 0x800217 DeviceID DEC 8389143
-
Smart Task
Smart Task name Base logics Logic function Direct
AND
OR
Window
Hysteresis
Timer function Deactivated
On delay
Off delay
ON and OFF delay
Impulse (one shot)
Inverter Yes Switching frequency SIO Direct: 170 Hz 1)
SIO Logic: 170 Hz 2)
IOL: 170 Hz 3)
Response time SIO Direct: 3 ms 1)
SIO Logic: 3 ms 2)
IOL: 3 ms 3)
Repeatability SIO Direct: 1,5 ms 1)
SIO Logic: 1,5 ms 2)
IOL: 1,5 ms 3)
Switching signal Switching signal QL1 Switching output Switching signal QL2 Switching output - 1) SIO Direct: sensor operation in standard I/O mode without IO-Link communication and without using internal sensor logic or time parameters (set to “direct”/”deactivated”).
- 2) SIO Logic: Sensor operation in standard I/O mode without IO-Link communication. Sensor-internal logic or timing parameters plus Automation Functions used.
- 3) IOL: Sensor operation with full IO-Link communication and usage of logic, timing and Automation Function parameters.
-
Diagnosis
Device status Yes Quality of teach Yes Quality of run Yes, Contamination display
-
Classifications
eCl@ss 5.0 27270902 eCl@ss 5.1.4 27270902 eCl@ss 6.0 27270902 eCl@ss 6.2 27270902 eCl@ss 7.0 27270902 eCl@ss 8.0 27270902 eCl@ss 8.1 27270902 eCl@ss 9.0 27270902 eCl@ss 10.0 27270902 eCl@ss 11.0 27270902 eCl@ss 12.0 27270902 ETIM 5.0 EC002717 ETIM 6.0 EC002717 ETIM 7.0 EC002717 ETIM 8.0 EC002717 UNSPSC 16.0901 39121528