Key Commercial Data
Orderkey | 2909575 |
---|---|
Packing unit | 1 pc |
GTIN | 4055626356471 |
Weight per Piece (excluding packing) | 248.450 g |
Custom tariff number | 85044030 |
Country of origin | DE (Germany) |
Ambient conditions
Degree of protection | IP20 |
---|---|
Ambient temperature (operation) | -25 °C … 70 °C (> 60 °C Derating: 2.5 %/K) |
Ambient temperature (start-up type tested) | -40 °C |
Ambient temperature (storage/transport) | -40 °C … 85 °C |
Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) |
Climatic class | 3K3 (in acc. with EN 60721) |
Degree of pollution | 2 |
Installation height | ≤ 5000 m (> 2000 m, observe derating) |
Input data
Input voltage range | 100 V AC … 240 V AC -15 % … +10 % |
---|---|
110 V DC … 250 V DC -20 % … +40 % | |
Dielectric strength maximum | 300 V AC 30 s |
Discharge current to PE | < 0.25 mA (264 V AC, 60 Hz) |
Current consumption | 0.46 A (100 V AC) |
0.37 A (120 V AC) | |
0.2 A (230 V AC) | |
0.2 A (240 V AC) | |
Nominal power consumption | 37 VA |
Inrush surge current | typ. 14 A (at 25 °C) |
Mains buffering | typ. 43 ms (120 V AC) |
typ. 43 ms (230 V AC) | |
Input fuse | 3.15 A (slow-blow, internal) |
Type of protection | Transient surge protection |
Protective circuit/component | Varistor |
Output data
Nominal output voltage | 24 V DC |
---|---|
Setting range of the output voltage (USet) | 24 V DC … 28 V DC (constant capacity) |
Nominal output current (IN) | 1.3 A |
Static Boost (IStat.Boost) | 1.625 A (≤ 40 °C) |
Dynamic Boost (IDyn.Boost) | 2.6 A (≤ 60 °C (5 s)) |
Derating | > 60 °C (2.5%/K) |
Connection in parallel | Yes, for redundancy and increased capacity |
Connection in series | yes |
Feedback resistance | ≤ 35 V DC |
Protection against surge voltage on the output | ≤ 32 V DC |
Control deviation | < 0.5 % (Static load change 10 % … 90 %) |
< 2 % (Dynamic load change 10 % … 90 %, (10 Hz)) | |
< 0.1 % (change in input voltage ±10 %) | |
Residual ripple | < 40 mVPP(with nominal values) |
Output power | 30 W |
Typical response time | 500 ms |
Maximum power dissipation in no-load condition | < 0.4 W (230 V AC) |
< 0.4 W (120 V AC) | |
Power loss nominal load max. | < 3.7 W (120 V AC) |
< 3.1 W (230 V AC) |
General
Net weight | 0.188 kg |
---|---|
Efficiency | typ. 89.2 % (120 V AC) |
typ. 90.7 % (230 V AC) | |
Insulation voltage input/output | 4 kV AC (type test) |
3 kV AC (routine test) | |
Protection class | II |
Degree of protection | IP20 |
MTBF (IEC 61709, SN 29500) | > 1904000 h (25 °C) |
> 1107000 h (40 °C) | |
> 486000 h (60 °C) | |
Assembly instructions | DIN rail mounting |