Key Commercial Data
Orderkey | 3050387 |
---|---|
Packing unit | 50 pc |
Minimum order quantity | 50 pc |
Catalog page | Page 210 (C-1-2017) |
GTIN | 4046356056229 |
Weight per Piece (excluding packing) | 17.990 g |
Custom tariff number | 85369095 |
Country of origin | CN (China) |
General
Note | The current is determined by the fuse used, the voltage by the selected LED. If the fuse is faulty, the downstream circuit will not be disconnected. |
---|---|
Number of levels | 1 |
Number of connections | 2 |
Nominal cross section | 2.5 mm² |
Color | black |
Insulating material | PA |
Flammability rating according to UL 94 | V0 |
Area of application | Railway industry |
Machine building | |
Plant engineering | |
Maximum power dissipation for nominal condition | 1.6 W |
Fuse | G / 5 x 20 |
Fuse type | Glass / ceramics / … |
Rated surge voltage | 4 kV |
Degree of pollution | 3 |
Overvoltage category | III |
Insulating material group | I |
Maximum power dissipation | max. 1.6 W (With single arrangement of the fuse terminal block in the event of overload) |
max. 1.6 W (With interconnected arrangement of several fuse terminal blocks in the event of overload) | |
max. 4 W (With single arrangement of the fuse terminal block in the event of a short-circuit) | |
max. 2.5 W (With interconnected arrangement of several fuse terminal blocks in the event of a short-circuit) | |
LED voltage range | 110 V AC/DC … 250 V AC/DC |
LED current range | 0.41 mA … 0.96 mA |
Connection in acc. with standard | IEC 60947-7-3 |
Maximum load current | 6.3 A (the current is determined by the fuse used) |
Nominal current IN | 6.3 A |
Nominal voltage UN | 250 V |
Open side panel | Yes |
Relative insulation material temperature index (Elec., UL 746 B) | 130 °C |
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) | 130 °C |
Static insulating material application in cold | -60 °C |
Behavior in fire for rail vehicles (DIN 5510-2) | Test passed |
Flame test method (DIN EN 60695-11-10) | V0 |
Oxygen index (DIN EN ISO 4589-2) | >32 % |
NF F16-101, NF F10-102 Class I | 2 |
NF F16-101, NF F10-102 Class F | 2 |
Surface flammability NFPA 130 (ASTM E 162) | passed |
Specific optical density of smoke NFPA 130 (ASTM E 662) | passed |
Smoke gas toxicity NFPA 130 (SMP 800C) | passed |
Calorimetric heat release NFPA 130 (ASTM E 1354) | 28 MJ/kg |
Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 – HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 – HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 – HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 – HL 3 |
Connection data
Conductor cross section solid min. | 0.5 mm² |
---|---|
Conductor cross section solid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.5 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 20 |
Conductor cross section AWG max. | 14 |
Connection method | Quick connection |
Max. wire diameter incl. insulation | 3.8 mm |
Standards and Regulations
Connection in acc. with standard | CSA |
---|---|
IEC 60947-7-3 | |
Flammability rating according to UL 94 | V0 |
Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 – HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 – HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 – HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 – HL 3 |
Environmental Product Compliance
China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
---|---|
No hazardous substances above threshold values |