Key Commercial Data
Orderkey | 1642182 |
---|---|
Packing unit | 1 pc |
Catalog page | Page 468 (C-2-2017) |
GTIN | 4017918951177 |
Weight per Piece (excluding packing) | 29.980 g |
Custom tariff number | 85366990 |
Country of origin | PL (Poland) |
General
Connection | If the conductor is reconnected, it must be cut off above the last contact point. QUICKON components may only be operated when under no load. |
---|---|
Color | black |
Locking type | without |
Connection method | QUICKON connection |
IDC connection | |
Number of positions | 4 |
Wrench size, union nut | 19 mm |
Tightening torque, union nut | 3 Nm |
Wrench size, contact carrier | 24 mm |
Number of connections | 4 |
Conductor cross section flexible min. | 0.75 mm² |
Conductor cross section flexible max. | 1.5 mm² |
Conductor cross section solid min. | 0.75 mm² |
Conductor cross section solid max. | 1 mm² |
Conductor cross section AWG min. | 18 |
Conductor cross section AWG max. | 16 |
Cabel
Structure of individual litz in acc. with VDE 0295 / smallest wire diameter | VDE 0295 class 1 to 6/min. 0.15 mm |
---|---|
Wire insulation material | PVC / PE |
Wire diameter including insulation | 1.8 mm … 3 mm |
External cable diameter | 6 mm … 12 mm |
Position marking | 1, 2, 3, PE |
Ambient conditions
Degree of protection | IP65 |
---|---|
IP67 | |
Ambient temperature (operation) | -40 °C … 80 °C (specifications of the cable manufacturer must also be observed) |
Ambient temperature (storage/transport) | -40 °C … 80 °C |
Temperature when conductor connected | -5 °C … 50 °C (specifications of the cable manufacturer must also be observed) |
Electrical characteristics
Nominal current IN | 15 A |
---|---|
Rated current | 15 A |
Rated voltage (III/3) | 500 V |
Rated voltage (III/2) | 800 V |
Rated voltage (II/2) | 1000 V |
Rated surge voltage (III/3) | 6 kV |
Rated surge voltage (III/2) | 6 kV |
Rated surge voltage (II/2) | 6 kV |
Mechanical characteristics
QUICKON connectability | max. 10 |
---|---|
Impact category | 3 |
Category of shock impact | IK06 |