Key Commercial Data
Orderkey | 1640744 |
---|---|
Packing unit | 10 pc |
Minimum order quantity | 10 pc |
Note | Made to Order (non-returnable) |
Catalog page | Page 19 (PC-2002) |
GTIN | 4017918177423 |
Weight per Piece (excluding packing) | 72.420 g |
Custom tariff number | 85366990 |
Country of origin | PL (Poland) |
General
Connection | If the conductor is reconnected, it must be cut off above the last contact point. QUICKON components may only be operated when under no load. |
---|---|
Length of cable | 0.5 m |
Color | green |
Locking type | Screw locking |
Connection method | QUICKON connection |
Individual wires | |
Number of positions | 4 |
Wrench size, union nut | 27 mm |
Tightening torque, union nut | 3.3 Nm |
Wrench size, contact carrier | 30 mm |
Tightening torque contact carrier | 5 Nm |
Tightening torque, counter nut | 5 Nm |
Number of connections | 4 |
Conductor cross section flexible min. | 0.75 mm² |
Conductor cross section flexible max. | 1.5 mm² |
Conductor cross section solid min. | 0.75 mm² |
Conductor cross section solid max. | 1.5 mm² |
Conductor cross section AWG min. | 18 |
Conductor cross section AWG max. | 16 |
Cabel
Structure of individual litz in acc. with VDE 0295 / smallest wire diameter | VDE 0295 Cl.2-5, min. wire diameter 0.2 mm |
---|---|
Wire insulation material | PVC / PE |
Wire diameter including insulation | 1.8 mm … 3 mm |
External cable diameter | 6 mm … 12 mm |
Conductor cross section | 1.5 mm² (Pos. 1: Brown; pos. 2: White; pos. 3: Blue; pos. 4: Black) |
Position marking | 1, 2, 3, 4 |
Ambient conditions
Degree of protection | IP65 |
---|---|
IP67 | |
Ambient temperature (operation) | -25 °C … 80 °C (specifications of the cable manufacturer must also be observed) |
-25 °C … 50 °C | |
Temperature when conductor connected | -5 °C … 50 °C (specifications of the cable manufacturer must also be observed) |
Electrical characteristics
Nominal current IN | 17.5 A |
---|---|
Rated current | 17.5 A |
Rated voltage (III/3) | 250 V |
Note on the rated voltage (III/3) | with insulating sleeve |
Rated voltage (III/2) | 320 V |
Note on the rated voltage (III/2) | with insulating sleeve |
Rated voltage (II/2) | 630 V |
Note on the rated voltage (II/2) | with insulating sleeve |
Rated surge voltage (III/3) | 6 kV |
Mechanical characteristics
QUICKON connectability | 10 (if the conductor is connected more than once, seal and cap may need to be replaced.) |
---|---|
PC QUICKON thread type | M25 x 1,5 |
Impact category | 4 |