Key Commercial Data
Orderkey | 2880024 |
---|---|
Packing unit | 10 pc |
Minimum order quantity | 10 pc |
Note | Made to Order (non-returnable) |
GTIN | 4017918956899 |
Weight per Piece (excluding packing) | 27.280 g |
Custom tariff number | 85369010 |
Country of origin | DE (Germany) |
Dimensions
Height | 44.8 mm |
---|---|
Width | 17.5 mm |
Depth | 51.7 mm |
Horizontal pitch | 1 Div. |
Complete module height | 90 mm |
Complete module width | 17.7 mm |
Complete module depth | 65.5 mm |
Ambient conditions
Ambient temperature (operation) | -40 °C … 85 °C |
---|---|
Ambient temperature (storage/transport) | -40 °C … 85 °C |
Altitude | ≤ 2000 m (amsl (above mean sea level)) |
Degree of protection | IP20 |
General
Housing material | PA 6.6 |
---|---|
Flammability rating according to UL 94 | V-0 |
Color | jet black RAL 9005 |
Mounting type | on base element |
Type | Male |
Direction of action | Line-Line & Line-Earth Ground |
Arrester can be tested with CHECKMASTER from software version: | From SW rev. 2.20 |
Additional descriptions
Note | Technical data is valid in association with the following specified base elements: |
---|---|
PT -BE/ FM 2839282 |
Protective circuit
IEC test classification | C1 |
---|---|
C2 | |
C3 | |
D1 | |
Nominal voltage UN | 230 V AC (50/60 Hz) |
Maximum continuous voltage UC | 320 V DC |
320 V AC (50/60 Hz) | |
Rated current | 26 A AC (30 °C) |
1 A DC | |
Operating effective current ICat UC | ≤ 200 µA AC |
≤ 10 µA DC | |
Residual current IPE | ≤ 400 µA AC |
≤ 20 µA DC | |
Nominal discharge current In(8/20) µs (line-earth) | 2.5 kA |
Pulse discharge current Iimp(10/350) µs | 500 A (per path) |
Total discharge current Itotal(8/20) µs | 5 kA |
Output voltage limitation at 1 kV/µs (line-earth) spike | ≤ 850 V |
Output voltage limitation at 1 kV/µs (line-earth) static | ≤ 850 V |
Voltage protection level Up(line-earth) | ≤ 850 V (C1 – 1.4 kV / 0.7 kA) |
≤ 1050 V (C2 – 5 kV/2,5 kA) | |
≤ 820 V (C3 – 100 A) | |
Response time tA(line-earth) | ≤ 25 ns |
Input attenuation aE, asym. | typ. 0.3 dB (≤ 500 kHz / 150 Ω) |
Cut-off frequency fg (3 dB), asym. (GND) in 150 Ohm system | typ. 1.7 MHz |
Capacity (line-earth) | typ. 2 nF |
Surge protection fault message | none |
Max. required back-up fuse | 25 A AC (gL/gG) |
1 A DC (T) | |
Impulse durability (line-earth) | C1 – 1,4 kV / 0,7 kA |
C2 – 5 kV/2.5 kA | |
C3 – 100 A | |
D1 – 500 A |