Key Commercial Data
Orderkey | 2904890 |
---|---|
Packing unit | 1 pc |
Note | Made to Order (non-returnable) |
GTIN | 4046356898171 |
Weight per Piece (excluding packing) | 152.800 g |
Custom tariff number | 90309000 |
Country of origin | IT (Italy) |
Measuring coil input data
Frequency measuring range | 40 Hz … 20000 Hz |
---|---|
Position error | < 1 % |
Linearity error | 0.1 % |
Measuring coil signal output
Output signal (at 50 Hz) | 100 mV (no load, at 1,000 A) |
---|---|
Output voltage (in no-load operation) | VOUT= M * dI/dt |
Output voltage (sinusoidal, in no-load operation) | 100 mV (VOUT= 2 * π * M * f * I (M = 0.318 μH; example: At 50 Hz; I = 1,000 A)) |
General data, measuring coil
Length of measuring coil | 300 mm |
---|---|
Diameter of measuring coil | 8.3 mm ±0.2 mm |
Length of signal cable | 3000 mm |
Conductor structure signal line | 2x 0.22 mm (Signal (tinned)) |
1x 0.22 mm (Shielding (tinned)) | |
Coil material | Elastollan |
Housing material | PC |
Insulation | double insulation |
Rated insulation voltage | 1000 V AC (rms CAT III) |
600 V AC (rms CAT IV) | |
Test voltage | 10.45 kV (DC / 1 min.) |
Basic accuracy | |
UL, USA/Canada | UL 61010 Recognized |
Ambient conditions
Ambient temperature (operation) | -30 °C … 80 °C (Measuring coil) |
---|---|
Ambient temperature (storage/transport) | -40 °C … 80 °C (Measuring coil) |
Maximum altitude | < 2000 m |
Measuring coil degree of protection | IP67 (not assessed by UL) |