Key Commercial Data
Orderkey | 1058044 |
---|---|
Packing unit | 1 |
Catalog page | Page 224 (C-5-2019) |
GTIN | 4055626702261 |
Custom tariff number | 85437090 |
Ambient conditions
Ambient temperature (operation) | -30 °C … 80 °C (Measuring coil) |
---|---|
-20 °C … 70 °C (Measuring transducer) | |
Ambient temperature (storage/transport) | -40 °C … 80 °C (Measuring coil) |
-25 °C … 85 °C (Measuring transducer) | |
Maximum altitude | < 2000 m |
Permissible humidity (operation) | 5 % … 95 % (non-condensing) |
Measuring coil degree of protection | IP67 (not assessed by UL) |
Measuring transducer degree of protection | IP20 |
Measuring transducer supply
Nominal supply voltage | 24 V DC -20 % … +25 % |
---|---|
Nominal supply voltage range | 19.2 V DC … 30 V DC |
Max. current consumption | 190 mA |
Power consumption | 4 W |
Measuring coil input data
Frequency measuring range | 40 Hz … 20000 Hz |
---|---|
Position error | < 1 % |
Linearity error | 0.1 % |
Measuring transducer input data
Measuring ranges (current) | 100 A 250 A 400 A 630 A 1000 A 1500 A 2000 A 4000 A |
---|---|
Configurable/programmable | Via DIP switches |
Phase angle | < 1 ° |
Rated power | 1.5 VA |
Max. distances for copper cables at PN max | 32 m (0.75 mm² (AWG 20)) |
64 m (1.5 mm² (AWG 16)) | |
107 m (2.5 mm² (AWG 14)) |
Measuring transducer signal input
Input signal (at 50 Hz) | 100 mV (1000 A) |
---|---|
Input impedance | 27 kΩ (smallest measuring range) |
Measuring coil signal output
Output signal (at 50 Hz) | 100 mV (no load, at 1,000 A) |
---|---|
Output voltage (in no-load operation) | VOUT= M * dI/dt |
Output voltage (sinusoidal, in no-load operation) | 100 mV (VOUT= 2 * π * M * f * I (M = 0.318 μH; example: At 50 Hz; I = 1,000 A)) |
General data, measuring coil
Length of measuring coil | 450 mm |
---|---|
Diameter of measuring coil | 8.3 mm ±0.2 mm |
Length of signal cable | 3000 mm |
Conductor structure signal line | 2x 0.22 mm (Signal (tinned)) |
1x 0.22 mm (Shielding (tinned)) | |
Coil material | Elastollan |
Housing material | PC |
Insulation | double insulation |
Rated insulation voltage | 1000 V AC (rms CAT III) |
600 V AC (rms CAT IV) | |
Test voltage | 10.45 kV (DC / 1 min.) |
Basic accuracy |
General data for measuring transducer
Linearity error | < 0.5 % (From the range end value) |
---|---|
Maximum transmission error | ≤ 0.5 % (From the range end value) |
Frequency range | 45 Hz … 65 Hz |
Max. detectable harmonics | < 2 kHz |
Current consumption | < 190 mA (at 19.2 V) |
Housing material | Polyamide |
Test voltage | 1.5 kV AC (Supply/input and output: 50 Hz, 1 min) |
Operating voltage display | Green LED |
UL, USA/Canada | UL 508 Listed |
General data
Standards/regulations | IEC 61010-1 |
---|---|
IEC 61010-2-032 | |
Insulation | double insulation |
Temperature coefficients | 0.005 %/K (+10°C … +70°C; both components have the same ambient temperature) |
0.07 %/K (-20°C … +10°C; both components have the same ambient temperature) | |
Typical measuring error | < 1 % |
Connection data
Connection name | Measuring transducer side |
---|---|
Connection method | Screw connection |
Stripping length | 7 mm |
Screw thread | M3 |
Conductor cross section solid | 0.2 mm² … 2.5 mm² |
Conductor cross section flexible | 0.2 mm² … 2.5 mm² |
Conductor cross section AWG | 24 … 14 |
Torque | 0.5 Nm … 0.6 Nm |
Standards and Regulations
Standards/regulations | IEC 61010-1 |
---|---|
IEC 61010-2-032 | |
Insulation | double insulation |
Pollution degree | 2 |
Overvoltage category | III (1000 V, to neutral conductor) |
IV (600 V, to neutral conductor) |
Environmental Product Compliance
REACh SVHC | Lead 7439-92-1 |
---|---|
China RoHS | Environmentally Friendly Use Period = 50 |
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer’s declaration” |
Classifications
[email protected]
[email protected] 4.0 | 27210900 |
---|---|
[email protected] 4.1 | 27210900 |
[email protected] 5.0 | 27210900 |
[email protected] 5.1 | 27210900 |
[email protected] 6.0 | 27210900 |
[email protected] 7.0 | 27210902 |
[email protected] 9.0 | 27210902 |