Features
Functional principle Photoelectric proximity sensor Functional principle detail Background suppression Actuator Pneumatic, valve on board Max. number of sensors Approx. 30 1) Logical principle of operation Single accumulation, single release, block (slug) release Dimensions (W x H x D) 51.5 mm x 151.4 mm x 46 mm Sensing range max. 300 mm … 900 mm Sensing range 300 mm … 900 mm Type of light Infrared light Light source LED 2) Light spot size (distance) Ø 40 mm (900 mm) Adjustment Potentiometer Special applications ZoneControl - 1) Maximum per individual incoming power supply at 27.6 V DC.
- 2) Average service life: 100,000 h at TU = +25 °C.
-
Mechanics/electronics
Supply voltage 21.6 V DC … 27.6 V DC 1) Ripple < 5 Vpp 2) Current consumption 25 mA 3) Switching output PNP Switching mode Dark switching Signal voltage PNP HIGH/LOW Approx. UV – < 2.0 V/0 V Output current Imax. ≤ 100 mA Switching frequency 250 Hz Connection type Male connector M12, 4-pin Connection type for daisy chain Cable with female connector, M12, 4-pin, 1.2 m Circuit protection A 4)
C 5)
D 6)
Protection class II 7) Weight 175 g Housing material Plastic, ABS Enclosure rating IP54 Shock and vibration resistance According to IEC 68 Ambient operating temperature –10 °C … +55 °C Ambient temperature, storage –25 °C … +75 °C UL File No. NRKH.E181493 & NRKH7.E181493 Medium for valves Compressed air or neutral gases filtered, non-lubricated or lubricated Design solenoid valve 3/2-way valve 8) Mode of operation solenoid valve Air to Brake (NO) Connection type solenoid valve Compressed air 2 x 8 mm diameter, output line 4 mm diameter Coil ratings 24 V DC 1 W Air flow rate Approx. 20 Nl/min 9) Ventilation capacity Approx. 130 Nl/min Operating pressure range 2 bar … 8 bar 10) - 1) Limit values.
- 2) May not exceed or fall below Uv tolerances.
- 3) Without load and valve deenergized.
- 4) A = VS connections reverse-polarity protected.
- 5) C = interference suppression.
- 6) D = outputs overcurrent and short-circuit protected.
- 7) Reference voltage: 50 V DC.
- 8) Other valve types available on request.
- 9) P – A.
- 10) In combination with cylinders with small air volume we recommend tests.
-
Pneumatic
Coil ratings 24 V DC 1 W Medium for valves Compressed air or neutral gases filtered, non-lubricated or lubricated Design solenoid valve 3/2-way valve 1) Connection type solenoid valve Compressed air 2 x 8 mm diameter, output line 4 mm diameter Air flow rate Approx. 20 Nl/min 2) Ventilation capacity Approx. 130 Nl/min Operating pressure range 2 bar … 8 bar 3) - 1) Other valve types available on request.
- 2) P – A.
- 3) In combination with cylinders with small air volume we recommend tests.
-
Classifications
eCl@ss 5.0 27270904 eCl@ss 5.1.4 27270904 eCl@ss 6.0 27270904 eCl@ss 6.2 27270904 eCl@ss 7.0 27270904 eCl@ss 8.0 27270904 eCl@ss 8.1 27270904 eCl@ss 9.0 27270904 eCl@ss 10.0 27270904 eCl@ss 11.0 27270904 eCl@ss 12.0 27270903 ETIM 5.0 EC002719 ETIM 6.0 EC002719 ETIM 7.0 EC002719 ETIM 8.0 EC002719 UNSPSC 16.0901 39121528