Features
Functional principle Photoelectric proximity sensor Functional principle detail Background suppression, Optical time-of-flight Dimensions (W x H x D) 17.4 mm x 45.6 mm x 34.7 mm Housing design (light emission) Rectangular Sensing range max. 200 mm … 3,000 mm 1) Sensing range 200 mm … 3,000 mm 2)
1)
Type of light Visible red light Light source Laser 3) Light spot size (distance) Ø 12 mm (3,000 mm) Wave length 658 nm Laser class 1 (IEC 60825-1 / CDRH 21 CFR 1040.10 & 1040.11) Adjustment Single teach-in button (4 x)
Display
- 1) Object with 6 … 90 % remission (based on standard white to DIN 5033).
- 2) Adjustable.
- 3) Average service life: 100,000 h at TU = +25 °C.
-
Mechanics/electronics
Supply voltage 10 V DC … 30 V DC 1) Ripple < 5 Vpp 2) Current consumption 75 mA 3) Switching output PNP 4)
NPN 5)
Number of switching outputs 2 (Q1, Q2) 4) Switching mode Light/dark switching 4) Switching mode selector Selectable via menu Output current Imax. ≤ 100 mA Response time 0.6 ms 6)
1 ms 7)
3.4 ms 8)
13 ms
51.4 ms
Switching frequency 833 Hz 9)
500 Hz 7)
147 Hz 8)
38 Hz
10 Hz
Time functions Without time delay
Off delay
On delay
One shot
Delay time Programmable, 0 ms … 999 ms Analog output – Input MFin = multifunctional input programmable 10) Connection type Male connector M8, 4-pin Circuit protection A 11)
B 12)
C 13)
Protection class III Weight 25 g Housing material Plastic, ABS Optics material Plastic, PMMA Enclosure rating IP67 Items supplied BEF-W190 mounting bracket Ambient operating temperature –30 °C … +50 °C 14) Ambient temperature, storage –40 °C … +70 °C Warm-up time < 5 min 15) Initialization time < 300 ms - 1) Limit values. Operated in short-circuit protected network: max. 8 A.
- 2) May not exceed or fall below Uv tolerances.
- 3) Without load. At VS = 24 V.
- 4) Q1, Q2 = 2 switching thresholds, light/dark switching selectable via light/dark selector.
- 5) PNP/NPN switchable.
- 6) Signal transit time with resistive load.
- 7) Can be set via a mean value filter (AVG1, AVG4, AVG16, AVG64, AVG256).
- 8) Depending on distance to object, distance to background and selected switching threshold.
- 9) With light/dark ratio 1:1.
- 10) External teach-in via cable, laser shutdown.
- 11) A = VS connections reverse-polarity protected.
- 12) B = inputs and output reverse-polarity protected.
- 13) C = interference suppression.
- 14) Uv ≥ 24 V. At Tu < –10 °C warm-up time < 10 min.
- 15) For optimum performance observe max. warm-up time of 5 minutes.
-
Safety-related parameters
MTTFD 174.4 years DCavg 0 %
-
Classifications
eCl@ss 5.0 27270904 eCl@ss 5.1.4 27270904 eCl@ss 6.0 27270904 eCl@ss 6.2 27270904 eCl@ss 7.0 27270904 eCl@ss 8.0 27270904 eCl@ss 8.1 27270904 eCl@ss 9.0 27270904 eCl@ss 10.0 27270904 eCl@ss 11.0 27270904 eCl@ss 12.0 27270903 ETIM 5.0 EC002719 ETIM 6.0 EC002719 ETIM 7.0 EC002719 ETIM 8.0 EC002719 UNSPSC 16.0901 39121528