Features
Functional principle Photoelectric proximity sensor Functional principle detail Background suppression, Optical time-of-flight Dimensions (W x H x D) 20 mm x 49.6 mm x 44.2 mm Housing design (light emission) Rectangular Sensing range max. 50 mm … 1,800 mm 1) Sensing range 100 mm … 1,800 mm 2)
1)
Distance value Measuring range 100 mm … 1,800 mm 1) Resolution 1 mm Repeatability 1,2 mm … 3,0 mm 3) 4) 5) Accuracy Typ. ± 20 mm 6) Typ. ± 15 mm 7) Type of light Visible red light Light source Laser 8) Light spot size (distance) Ø 12 mm (1,800 mm) Wave length 658 nm Laser class 1 (IEC 60825-1 / CDRH 21 CFR 1040.10 & 1040.11) Adjustment Single teach-in button (2 x) - 1) Object with 6 … 90 % remission (based on standard white to DIN 5033).
- 2) Adjustable.
- 3) Equivalent to 1 σ.
- 4) See characteristic curves repeatability.
- 5) 6% … 90% remission factor.
- 6) 50 … 1000 mm.
- 7) 1000 … 1800 mm.
- 8) Average service life: 100,000 h at TU = +25 °C.
-
Mechanics/electronics
Supply voltage 12 V DC … 30 V DC 1) 2) Ripple < 5 Vpp 3) Current consumption 70 mA 4) Switching output Push-pull: PNP/NPN 5) Number of switching outputs 1 (Q1) 5) Switching mode Light switching 5) Output current Imax. ≤ 50 mA Response time ≤ 5 ms 6) Switching frequency 100 Hz 7) Analog output 4 mA … 20 mA (≤ 450 Ω) / 0 V … 10 V (≥ 50 kΩ) / switchable Resolution of analog output 12 bit Output time ≤ 5 ms Input Sender off Connection type Male connector M12, 5-pin Circuit protection A 8)
B 9)
C 10)
Protection class III Weight 48 g Housing material Plastic, VISTAL® Optics material Plastic, PMMA Enclosure rating IP67 Ambient operating temperature –35 °C … +50 °C 11) Ambient temperature, storage –40 °C … +70 °C Warm-up time < 15 min 12) Initialization time < 300 ms UL File No. NRKH.E181493 - 1) Limit values. Operated in short-circuit protected network: max. 8 A.
- 2) Vs min when using the voltage output = 13 V.
- 3) May not exceed or fall below Uv tolerances.
- 4) Without load. At VS = 24 V.
- 5) Q1 = 1 switching threshold, light switching.
- 6) Signal transit time with resistive load.
- 7) With light/dark ratio 1:1.
- 8) A = VS connections reverse-polarity protected.
- 9) B = inputs and output reverse-polarity protected.
- 10) C = interference suppression.
- 11) For Vs ≤ 24 V. When Tu = 45 °C or above, a maximum load resistance of 300 Ω … 450 Ω is permitted on QA.
- 12) Below Tu = –10 °C a warm-up time is necessary.
-
Safety-related parameters
MTTFD 124 years DCavg 0 % TM (mission time) 20 years
-
Classifications
eCl@ss 5.0 27270904 eCl@ss 5.1.4 27270904 eCl@ss 6.0 27270904 eCl@ss 6.2 27270904 eCl@ss 7.0 27270904 eCl@ss 8.0 27270904 eCl@ss 8.1 27270904 eCl@ss 9.0 27270904 eCl@ss 10.0 27270904 eCl@ss 11.0 27270904 eCl@ss 12.0 27270903 ETIM 5.0 EC002719 ETIM 6.0 EC002719 ETIM 7.0 EC002719 ETIM 8.0 EC002719 UNSPSC 16.0901 39121528