Features
Functional principle Photoelectric proximity sensor Functional principle detail Background suppression Sensing range max. 25 mm … 300 mm 1) Sensing range 25 mm … 300 mm 1) Emitted beam Light source Laser 2) Type of light Visible red light Light spot size (distance) Ø 1 mm (170 mm) Key laser figures Normative reference EN 60825-1:2014, IEC 60825-1:2014 / CDRH 21 CFR 1040.10 & 1040.11 Laser class 1 Wave length 650 nm Adjustment Potentiometer, 5 turns Special applications Detecting small objects Mounting hole M3 - 1) Object with 90% remission (based on standard white, DIN 5033).
- 2) Average service life: 50,000 h at TU = +25 °C.
-
Safety-related parameters
MTTFD 420 years (EN ISO 13849-1) 1) DCavg 0 % - 1) Mode of calculation: Parts-Count-calculation.
-
Electrical data
Supply voltage UB 10 V DC … 30 V DC 1) Ripple < 5 Vpp 2) Current consumption 30 mA 3) Protection class III Digital output Type PNP Output current Imax. ≤ 100 mA Response time ≤ 0.5 ms 4) Switching frequency 1,000 Hz 5) Switching mode Light switching Circuit protection A 6)
B 7)
C 8)
- 1) Limit values when operated in short-circuit protected network: max. 8 A.
- 2) May not exceed or fall below Uv tolerances.
- 3) Without load.
- 4) Signal transit time with resistive load.
- 5) With light/dark ratio 1:1.
- 6) A = VS connections reverse-polarity protected.
- 7) B = inputs and output reverse-polarity protected.
- 8) C = interference suppression.
-
Mechanical data
Housing Rectangular Design detail Slim Dimensions (W x H x D) 12.2 mm x 41.8 mm x 17.3 mm Connection Cable with connector M8, 3-pin 1) Connection detail Conductor size 0.14 mm² Length of cable (L) 100 mm 1) Material Housing Plastic, Novodur Front screen Plastic, PMMA Cable PVC Weight 100 g - 1) Do not bend below 0 °C.
-
Ambient data
Enclosure rating IP66
IP67
Ambient operating temperature –10 °C … +50 °C Ambient operating temperature extended –30 °C … +55 °C 1) 2) Ambient temperature, storage –30 °C … +70 °C RoHS certificate ✔ - 1) As of Ta = 50 °C, a max. supply voltage Vmax. = 24 V and a max. load current Imax. = 50 mA is permitted.
- 2) Operation below Tu –10 °C is possible if the sensor is already switched on at Tu > –10 °C, then cools down, and the supply voltage is subsequently not switched off. Switching on below Tu –10 °C is not permissible.
-
Classifications
eCl@ss 5.0 27270904 eCl@ss 5.1.4 27270904 eCl@ss 6.0 27270904 eCl@ss 6.2 27270904 eCl@ss 7.0 27270904 eCl@ss 8.0 27270904 eCl@ss 8.1 27270904 eCl@ss 9.0 27270904 eCl@ss 10.0 27270904 eCl@ss 11.0 27270904 eCl@ss 12.0 27270903 ETIM 5.0 EC002719 ETIM 6.0 EC002719 ETIM 7.0 EC002719 ETIM 8.0 EC002719 UNSPSC 16.0901 39121528