Features
Functional principle Photoelectric retro-reflective sensor Functional principle detail Autocollimation Sensing range max. 0 m … 12 m 1) Sensing range 0 m … 8 m 1) Polarisation filters Yes Emitted beam Light source Laser 2) Type of light Visible red light Light spot size (distance) Ø 1 mm (500 mm) Key laser figures Normative reference EN 60825-1:2014, IEC 60825-1:2014 / CDRH 21 CFR 1040.10 & 1040.11 Laser class 1 Wave length 650 nm Adjustment IO-Link
Single teach-in button
Special applications Detecting small objects Mounting hole M3 Pin 2 configuration External input, Teach-in input, Sender off input, Detection output, logic output, Device contamination alarm output - 1) Reflector PL80A.
- 2) Average service life: 50,000 h at TU = +25 °C.
-
Safety-related parameters
MTTFD 562 years (EN ISO 13849-1) 1) DCavg 0 % TM (mission time) 10 years - 1) Mode of calculation: Parts-Count-calculation.
-
Communication interface
IO-Link ✔ , COM2 (38,4 kBaud) Data transmission rate COM2 (38,4 kBaud) Cycle time 2.3 ms Process data length 16 Bit Process data structure Bit 0 = switching signal QL1 Bit 1 = switching signal QL2 Bit 2 … 15 = empty VendorID 26 DeviceID HEX 0x80010F DeviceID DEC 8388879
-
Electrical data
Supply voltage UB 10 V DC … 30 V DC 1) Ripple < 5 Vpp 2) Current consumption 30 mA 3) Protection class III Digital output Type PNP 4) Output current Imax. ≤ 100 mA Response time ≤ 0.5 ms 5) Repeatability (response time) 150 µs 6) Switching frequency 1,000 Hz 7) Switching mode Light/dark switching 4) Output function Complementary Circuit protection A 8)
B 9)
C 10)
Response time Q/ on Pin 2 300 µs … 450 µs 5) 6) Switching frequency Q / to pin 2 1,000 Hz 11) - 1) Limit values when operated in short-circuit protected network: max. 8 A.
- 2) May not exceed or fall below Uv tolerances.
- 3) Without load.
- 4) Q = light switching.
- 5) Signal transit time with resistive load.
- 6) Valid for Q on Pin2, if configured with software.
- 7) With light/dark ratio 1:1.
- 8) A = VS connections reverse-polarity protected.
- 9) B = inputs and output reverse-polarity protected.
- 10) C = interference suppression.
- 11) With light / dark ratio 1:1, valid for Q on Pin2, if configured with software.
-
Mechanical data
Housing Rectangular Design detail Slim Dimensions (W x H x D) 12.2 mm x 41.8 mm x 17.3 mm Connection Male connector M8, 4-pin Material Housing Plastic, Novodur Front screen Plastic, PMMA Weight 100 g
-
Ambient data
Enclosure rating IP66
IP67
Ambient operating temperature –10 °C … +50 °C Ambient operating temperature extended –30 °C … +55 °C 1) 2) Ambient temperature, storage –30 °C … +70 °C UL File No. NRKH.E181493 - 1) As of Ta = 50 °C, a max. supply voltage Vmax. = 24 V and a max. load current Imax. = 50 mA is permitted.
- 2) Operation below Tu –10 °C is possible if the sensor is already switched on at Tu > –10 °C, then cools down, and the supply voltage is subsequently not switched off. Switching on below Tu –10 °C is not permissible.
-
Smart Task
Smart Task name Base logics Logic function Direct
AND
OR
WINDOW
Hysteresis
Timer function Deactivated
On delay
Off delay
ON and OFF delay
Impulse (one shot)
Inverter Yes Switching frequency SIO Direct: 1000 Hz 1)
SIO Logic: 1000 Hz 2)
IOL: 900 Hz 3)
Response time SIO Direct: 300 µs … 450 µs 1)
SIO Logic: 500 µs … 600 µs 2)
IOL: 500 µs … 900 µs 3)
Repeatability SIO Direct: 150 µs 1)
SIO Logic: 150 µs 2)
IOL: 400 µs 3)
Switching signal Switching signal QL1 Switching output Switching signal QL2 Switching output - 1) SIO Direct: sensor operation in standard I/O mode without IO-Link communication and without using internal sensor logic or time parameters (set to “direct”/”deactivated”).
- 2) SIO Logic: Sensor operation in standard I/O mode without IO-Link communication. Sensor-internal logic or timing parameters plus Automation Functions used.
- 3) IOL: Sensor operation with full IO-Link communication and usage of logic, timing and Automation Function parameters.
-
Diagnosis
Device status Yes Quality of teach Yes Quality of run Yes, Contamination display
-
Classifications
eCl@ss 5.0 27270902 eCl@ss 5.1.4 27270902 eCl@ss 6.0 27270902 eCl@ss 6.2 27270902 eCl@ss 7.0 27270902 eCl@ss 8.0 27270902 eCl@ss 8.1 27270902 eCl@ss 9.0 27270902 eCl@ss 10.0 27270902 eCl@ss 11.0 27270902 eCl@ss 12.0 27270902 ETIM 5.0 EC002717 ETIM 6.0 EC002717 ETIM 7.0 EC002717 ETIM 8.0 EC002717 UNSPSC 16.0901 39121528