Features
Functional principle Photoelectric proximity sensor Functional principle detail Background suppression Sensing range Sensing range min. 4 mm Sensing range max. 220 mm Adjustable switching threshold for background suppression 15 mm … 220 mm Reference object Object with 90% remission factor (complies with standard white according to DIN 5033) Minimum distance between set sensing range and background (black 6% / white 90%) 3 mm, at a distance of 80 mm Recommended sensing range for the best performance 40 mm … 140 mm Emitted beam Light source PinPoint LED Type of light Visible red light Shape of light spot Point-shaped Light spot size (distance) Ø 4.2 mm (130 mm) Maximum dispersion of the emitted beam around the standardized transmission axis (squint angle) < +/- 1.5° (at Ta = +23 °C) Key LED figures Normative reference EN 62471:2008-09 | IEC 62471:2006, modified LED risk group marking Free group Wave length 635 nm Average service life 100,000 h at Ta = +25 °C Smallest detectable object (MDO) typ. 0.2 mm (At 130 mm distance (object with 90% remission (complies with standard white according to DIN 5033))) Adjustment Teach-Turn adjustment BluePilot: For setting the sensing range IO-Link For configuring the sensor parameters and Smart Task functions Indication LED blue BluePilot: sensing range indicator LED green Operating indicator
Static on: power on
Flashing: IO-Link modeLED yellow Status of received light beam
Static on: object present
Static off: object not present
-
Safety-related parameters
MTTFD 642 years DCavg 0 % TM (mission time) 20 years (EN ISO 13849)
Rate of use: 60 %
-
Communication interface
IO-Link ✔ , IO-Link V1.1 Data transmission rate COM2 (38,4 kBaud) Cycle time 2.3 ms Process data length 16 Bit Process data structure Bit 0 = switching signal QL1 Bit 1 = switching signal QL2 Bit 2 … 15 = Current receiver level (live) VendorID 26 DeviceID HEX 0x80024A DeviceID DEC 8389194 Compatible master port type A SIO mode support Yes
-
Electrical data
Supply voltage UB 10 V DC … 30 V DC 1) Ripple ≤ 5 Vpp Usage category DC-12 (According to EN 60947-5-2)
DC-13 (According to EN 60947-5-2)
Current consumption ≤ 25 mA, without load. At UB = 24 V Protection class III Digital output Number 2 (Complementary) Type Push-pull: PNP/NPN Signal voltage PNP HIGH/LOW Approx. UB-2.5 V / 0 V Signal voltage NPN HIGH/LOW Approx. UB / < 2.5 V Output current Imax. ≤ 100 mA Circuit protection outputs Reverse polarity protected Overcurrent protected Short-circuit protected Response time ≤ 500 µs 2) Repeatability (response time) 150 µs Switching frequency 1,000 Hz 3) Pin/Wire assignment Function of pin 4/black (BK) Digital output, light switching, object present → output QL1 HIGH; IO-Link communication C Function of pin 4/black (BK) – detail The pin 4 function of the sensor can be configured, Additional possible settings via IO-Link Function of pin 2/white (WH) Digital output, dark switching, object present → output ǬL1 LOW Function of pin 2/white (WH) – detail The pin 2 function of the sensor can be configured, Additional possible settings via IO-Link - 1) Limit values.
- 2) Signal transit time with resistive load in switching mode.
- 3) With light/dark ratio 1:1.
-
Mechanical data
Housing Rectangular Design detail Flat Dimensions (W x H x D) 16 mm x 40.1 mm x 12.1 mm Connection Cable with M8 male connector, 4-pin, 110 mm Connection detail Deep-freeze property Do not bend below 0 °C Conductor size 0.14 mm² Cable diameter Ø 3.4 mm Length of cable (L) 77 mm Material Housing Plastic, VISTAL® Front screen Plastic, PMMA Cable PVC Male connector Plastic, VISTAL® Weight Approx. 30 g Maximum tightening torque of the fixing screws 0.4 Nm
-
Ambient data
Enclosure rating IP66 (EN 60529)
IP67 (EN 60529)
Ambient operating temperature –40 °C … +60 °C Ambient temperature, storage –40 °C … +75 °C Typ. Ambient light immunity Artificial light: ≤ 50,000 lx
Sunlight: ≤ 50,000 lx
Shock resistance 30 g, 11 ms (3 positive and 3 negative shocks along X, Y, Z axes, 18 total shocks (EN60068-2-27)) Vibration resistance 10 Hz … 1,000 Hz (Amplitude 1 mm, 3 x 30 min (EN60068-2-6)) Air humidity 35 % … 95 %, Relative humidity (no condensation) Electromagnetic compatibility (EMC) EN 60947-5-2 Resistance to cleaning agent ECOLAB UL File No. NRKH.E181493 & NRKH7.E181493
-
Smart Task
Smart Task name Base logics Logic function Direct
AND
OR
Timer function Deactivated
On delay
Off delay
ON and OFF delay
Impulse (one shot)
Inverter Yes Switching frequency SIO Logic: 900 Hz 1)
IOL: 800 Hz 2)
Response time SIO Logic: 550 µs 1)
IOL: 600 µs 2)
Repeatability SIO Logic: 200 µs 1)
IOL: 250 µs 2)
Switching signal Switching signal QL1 Switching output Switching signal ǬL1 Switching output - 1) Use of Smart Task functions without IO-Link communication (SIO mode).
- 2) Use of Smart Task functions with IO-Link communication function.
-
Diagnosis
Device temperature Measuring range Very cold, cold, moderate, warm, hot Device status Yes Detailed device status Yes Operating hour counter Yes Operating hours counter with reset function Yes Quality of teach Yes
-
Classifications
eCl@ss 5.0 27270904 eCl@ss 5.1.4 27270904 eCl@ss 6.0 27270904 eCl@ss 6.2 27270904 eCl@ss 7.0 27270904 eCl@ss 8.0 27270904 eCl@ss 8.1 27270904 eCl@ss 9.0 27270904 eCl@ss 10.0 27270904 eCl@ss 11.0 27270904 eCl@ss 12.0 27270903 ETIM 5.0 EC002719 ETIM 6.0 EC002719 ETIM 7.0 EC002719 ETIM 8.0 EC002719 UNSPSC 16.0901 39121528