Features
Functional principle Photoelectric retro-reflective sensor Functional principle detail Autocollimation Sensing range max. 0 m … 12 m 1) Sensing range 0 m … 8 m 1) Polarisation filters Yes Emitted beam Light source Laser 2) Type of light Visible red light Light spot size (distance) Ø 1 mm (500 mm) Key laser figures Normative reference EN 60825-1:2014, IEC 60825-1:2014 / CDRH 21 CFR 1040.10 & 1040.11 Laser class 1 Wave length 650 nm Adjustment IO-Link
Single teach-in button
Required accessories Auxiliary sensor (e.g. WL4SL-3P2232, 1061561), Smart-Sensor Y-junction SYL-8204-G0M11-X2 (6055012), 2 x connecting cable (e.g. YF8U14-C60VA3M8U14, 2096612), 2 x reflector (e.g. P250F, 5308843) Mounting hole M3 - 1) Reflector PL80A.
- 2) Average service life: 50,000 h at TU = +25 °C.
-
Safety-related parameters
MTTFD 562 years (EN ISO 13849-1) 1) DCavg 0 % TM (mission time) 10 years - 1) Mode of calculation: Parts-Count-calculation.
-
Communication interface
IO-Link ✔ , COM2 (38,4 kBaud) Data transmission rate COM2 (38,4 kBaud) Cycle time 2.3 ms Process data length 16 Bit Process data structure Bit 0 = switching signal QL1 Bit 1 = Detection signal Qint.1 Bit 2 … 15 = measuring value VendorID 26 DeviceID HEX 0x800222 DeviceID DEC 8389154
-
Electrical data
Supply voltage UB 10 V DC … 30 V DC 1) Ripple < 5 Vpp 2) Current consumption 30 mA 3) Protection class III Digital output Type PNP 4) Output current Imax. ≤ 100 mA Response time ≤ 0.5 ms 5) Repeatability (response time) 150 µs 6) Switching frequency 1,000 Hz 7) Switching mode Light/dark switching 4) Output function Complementary Circuit protection A 8)
B 9)
C 10)
Response time Q/ on Pin 2 300 µs … 450 µs 5) 6) Switching frequency Q / to pin 2 1,000 Hz 11) - 1) Limit values when operated in short-circuit protected network: max. 8 A.
- 2) May not exceed or fall below Uv tolerances.
- 3) Without load.
- 4) Q = light switching.
- 5) Signal transit time with resistive load.
- 6) Valid for Q on Pin2, if configured with software.
- 7) With light/dark ratio 1:1.
- 8) A = VS connections reverse-polarity protected.
- 9) B = inputs and output reverse-polarity protected.
- 10) C = interference suppression.
- 11) With light / dark ratio 1:1, valid for Q on Pin2, if configured with software.
-
Mechanical data
Housing Rectangular Design detail Slim Dimensions (W x H x D) 12.2 mm x 41.8 mm x 17.3 mm Connection Male connector M8, 4-pin Material Housing Plastic, Novodur Front screen Plastic, PMMA Weight 100 g
-
Ambient data
Enclosure rating IP66
IP67
Ambient operating temperature –10 °C … +50 °C Ambient operating temperature extended –30 °C … +55 °C 1) 2) Ambient temperature, storage –30 °C … +70 °C UL File No. NRKH.E181493 - 1) As of Ta = 50 °C, a max. supply voltage Vmax. = 24 V and a max. load current Imax. = 50 mA is permitted.
- 2) Operation below Tu –10 °C is possible if the sensor is already switched on at Tu > –10 °C, then cools down, and the supply voltage is subsequently not switched off. Switching on below Tu –10 °C is not permissible.
-
Smart Task
Smart Task name Speed and Length Monitoring Measurement mode Speed
Length
Length incremental
Relative measurement error related to the measured value ≤ 1 % Resolution measurement value 1 mm / 1 mm/s Logic function WINDOW Timer function Impulse width, impulse shift Max. pulse frequency at the external input (pin 2 / white wire) ≤ 1,000 Hz Switching signal Switching signal QL1 Switching output to measuring value switching thresholds Measuring value Speed measurement value / length measurement value
-
Diagnosis
Device status Yes Quality of teach Yes Quality of run Yes, Contamination display
-
Classifications
eCl@ss 5.0 27270902 eCl@ss 5.1.4 27270902 eCl@ss 6.0 27270902 eCl@ss 6.2 27270902 eCl@ss 7.0 27270902 eCl@ss 8.0 27270902 eCl@ss 8.1 27270902 eCl@ss 9.0 27270902 eCl@ss 10.0 27270902 eCl@ss 11.0 27270902 eCl@ss 12.0 27270902 ETIM 5.0 EC002717 ETIM 6.0 EC002717 ETIM 7.0 EC002717 ETIM 8.0 EC002717 UNSPSC 16.0901 39121528