Features
Functional principle Photoelectric retro-reflective sensor Functional principle detail Autocollimation Sensing range max. 0 m … 5 m 1) Sensing range 0 m … 3 m 1) Polarisation filters Yes Emitted beam Light source PinPoint LED 2) Type of light Visible red light Light spot size (distance) Ø 45 mm (1.5 m) Key LED figures Wave length 650 nm Adjustment IO-Link
Single teach-in button
Special applications Detecting transparent objects Pin 2 configuration External input, Teach-in input, Sender off input, Detection output, logic output, Device contamination alarm output AutoAdapt ✔ - 1) Reflector PL80A.
- 2) Average service life: 100,000 h at TU = +25 °C.
-
Safety-related parameters
MTTFD 1,222 years DCavg 0 %
-
Communication interface
IO-Link ✔ , COM2 (38,4 kBaud) Data transmission rate COM2 (38,4 kBaud) Cycle time 2.3 ms Process data length 16 Bit Process data structure Bit 0 = switching signal QL1 Bit 1 = switching signal QL2 Bit 2 … 15 = measuring value VendorID 26 DeviceID HEX 0x8000E0 DeviceID DEC 8388832
-
Electrical data
Supply voltage UB 10 V DC … 30 V DC 1) Ripple < 5 Vpp 2) Current consumption 20 mA 3) Protection class III Digital output Type PNP Output current Imax. ≤ 100 mA Repeatability (response time) 150 µs Switching frequency 1,000 Hz Attenuation along light beam > 8 % Switching mode Light/dark switching Circuit protection A 4)
B 5)
C 6)
D 7)
Response time Q/ on Pin 2 300 µs … 450 µs 8) 9) Switching frequency Q / to pin 2 1,000 Hz 10) Special feature Detecting transparent objects - 1) Limit values when operated in short-circuit protected network: max. 8 A.
- 2) May not exceed or fall below Uv tolerances.
- 3) Without load.
- 4) A = VS connections reverse-polarity protected.
- 5) B = inputs and output reverse-polarity protected.
- 6) C = interference suppression.
- 7) D = outputs overcurrent and short-circuit protected.
- 8) Signal transit time with resistive load.
- 9) Valid for Q on Pin2, if configured with software.
- 10) With light / dark ratio 1:1, valid for Q on Pin2, if configured with software.
-
Mechanical data
Housing Rectangular Design detail Slim Dimensions (W x H x D) 12.2 mm x 41.8 mm x 17.3 mm Connection Male connector M8, 4-pin Material Housing Plastic, ABS Front screen Plastic, PMMA Weight 30 g
-
Ambient data
Enclosure rating IP67
IP66
Ambient operating temperature –40 °C … +60 °C Ambient temperature, storage –40 °C … +75 °C UL File No. NRKH.E181493 & NRKH7.E181493
-
Smart Task
Smart Task name Counter + debouncing Logic function Direct
WINDOW
Hysteresis
Timer function Deactivated
On delay
Off delay
ON and OFF delay
Impulse (one shot)
Inverter Yes Response time 1)
2)
Repeatability 1)
2)
Maximum counting frequency SIO Direct: — 3)
SIO Logic: 1000 µs 1)
IOL: 900 µs 2)
Counter reset SIO Direct: —
SIO Logic: 1,5 ms
IOL: 1,5 ms
Min. Time between two process events (switches) SIO Direct: —
SIO Logic: 450 µs
IOL: 500 µs
Debounce time max. SIO Direct: —
SIO Logic: 30.000 ms
IOL: 30.000 ms
Switching signal Switching signal QL1 Output type (dependant on the adjusted threshold) Switching signal QL2 Output type (dependant on the adjusted threshold) Measuring value Counting value - 1) SIO Logic: Sensor operation in standard I/O mode without IO-Link communication. Sensor-internal logic or timing parameters plus Automation Functions used.
- 2) IOL: Sensor operation with full IO-Link communication and usage of logic, timing and Automation Function parameters.
- 3) SIO Direct: sensor operation in standard I/O mode without IO-Link communication and without using internal sensor logic or time parameters (set to “direct”/”deactivated”).
-
Diagnosis
Device status Yes Quality of teach Yes Quality of run Yes, Contamination display
-
Classifications
eCl@ss 5.0 27270902 eCl@ss 5.1.4 27270902 eCl@ss 6.0 27270902 eCl@ss 6.2 27270902 eCl@ss 7.0 27270902 eCl@ss 8.0 27270902 eCl@ss 8.1 27270902 eCl@ss 9.0 27270902 eCl@ss 10.0 27270902 eCl@ss 11.0 27270902 eCl@ss 12.0 27270902 ETIM 5.0 EC002717 ETIM 6.0 EC002717 ETIM 7.0 EC002717 ETIM 8.0 EC002717 UNSPSC 16.0901 39121528