Features
Items supplied Accessories not included with delivery, please order seperately.
-
Performance
Type 48 mm installation housing – IN cylinder mounting Pressure pipe/End cap 10 mm / Flat Connection type Connecting cable, 3-wire, 1,000 mm Direction of connection Radial Measuring range Measured values Positioning Position (F.S.) 0 mm … 350 mm 1) Null zone 30 mm Damping zone 63 mm Operating conditions Fluid temperature –30 °C … +95 °C 2) Air humidity 90 % (Condensation not permitted) Operating pressure PN 400 bar Supply voltage 12 V DC (8 … 16 V DC) Switch-on time < 250 ms Switch-on current Typ. 2.5 A/ 50 µs Measuring frequency (internal) 2 ms Transmission rate (cycle time) Steady Accuracy Setpoint tolerance ≤ ± 1 mm Resolution Typ. 0.1 mm (noise-free) Hysteresis ± 0,1 mm Repeatability Typ. ± 0.2 mm Linearity Typ. ± 0.25 mm (measuring range 50 to 500 mm) 3) Typ. ± 0.04% F.S. (measuring range from 500 to 2,500 mm) Temperature drift Warming up phase Typ. ≤ ± 0.25 mm (2 min) In the operational status Typ. ± 0.25 mm (measuring range 50 to 500 mm) 3) Typ. ± 0.04% F.S. (measuring range from 500 to 2,500 mm) MTTFd 69 years (EN ISO 13849-1) 4) - 1) F.S. = Full Scale (Measuring range).
- 2) Depends on the maximum fluid temperature, the permissible temperature of the O-ring and the temperature-dependent signal quality of the position magnet.
- 3) Hydraulic oil at operating temperature.
- 4) , This product is a standard product and does not constitute a safety component as defined in the Machinery Directive. Calculation based on nominal load of components, average ambient temperature of the electronics 60 °C, frequency of use 8,760 h/a.
Every 2nd failure of an electronic component is considered hazardous.
-
Interfaces
Communication interface Analog Communication Interface detail Voltage Voltage output 0.5 V DC … 4.5 V DC
-
Electrical data
Connection type Connecting cable, 3-wire, 1,000 mm Electrical operation Supply voltage 12 V DC (8 … 16 V DC) Residual ripple < 1% S-S Power consumption ≤ 0.75 W Current consumption ≤ 60 mA Load resistance RL ≥ 10 kΩ Overvoltage protection during power-up (60 s) ≤ 18 V at all poles during power-up (60 s)
≤ 24 V To GND during power-up (60 s)
Reverse polarity protection ≤ 36 V (at all poles) (ISO 16750-2) Insulation resistance Riso ≥ 10 MΩ, 60 s (ISO 16750-2) Dielectric strength 500 V DC, 0 V DC (60 s) to housing (RISO ≥ 1 MΩ) (ISO 16750-2) Short-circuit protection VS – GND on housing
-
Mechanical data
Dimensions Housing 48 mm, 48f7 for IN cylinder mounting – cylinder bore hole 48H8 Ø pressure pipe 10 mm Ø O-ring 40.87 mm x 3.53 mm Ø support ring 42.6 mm x 48 mm x 1.4 mm Ø connecting cable Ø 5.0 mm; 3 x 0.38 mm² (AWG22), stripped Length of cable 1,000 mm Material Housing Stainless steel 1.4305 (AISI 303) Pressure pipe Stainless steel 1.4404, AISI 316L O-ring NBR 70 Support ring PTFE Sheath PUR
-
Ambient data
EMC EU Directive 2014/30 / EU CE marking Generic standards EN 61000-6-2/61000-6-3 Agricultural and forestry machinery EN ISO 14982 Transient pulses ISO 7637-2/ISO 16750-2 ESD (air and contact discharge) ISO 61000-4-2 ISO 10605 Enclosure rating Housing IP67 (EN 60529) Temperature and air humidity Storage –20 °C … +65 °C 1) Operation (electronics) –40 °C … +105 °C 2) Maximum air humidity 90 % (Condensation not permitted) Vibration Sine 20 g (sine) / 55 … 2,000 Hz / 3×24 h (IEC 60068-2-6 Fc) Sine over noise 18 g (r.m.s) / 10 … 2,000 Hz / 3×36 h (IEC 60068-2-80 Fi) Broadband noise (resonance peaks removed) 20 g (r.m.s) / 10 … 2,000 Hz / 3×48 h (IEC 60068-2-64 Fh) Shock Drop test in acc. with IEC 60068-2-31
100 g, 11 ms (Single shock in acc. with IEC 60068-2-27)
50 g, 11 ms (Continuous shock: 1,000×50 g / 11 ms half sine)
Compressive load Operating pressure PN 400 bar Overload pressure Pmax = PN x 1.2 480 bar Test pressure Pstat = PN x 1.5 600 bar - 1) R. H. 55%.
- 2) Taking into account self-heating, generated through constant electrical operation with supply voltage.
-
Classifications
eCl@ss 5.0 27270705 eCl@ss 5.1.4 27270705 eCl@ss 6.0 27270705 eCl@ss 6.2 27270705 eCl@ss 7.0 27270705 eCl@ss 8.0 27270705 eCl@ss 8.1 27270705 eCl@ss 9.0 27270705 eCl@ss 10.0 27270705 eCl@ss 11.0 27270705 eCl@ss 12.0 27274304 ETIM 5.0 EC002544 ETIM 6.0 EC002544 ETIM 7.0 EC002544 ETIM 8.0 EC002544 UNSPSC 16.0901 41111613