Features
Dimensions 47 mm x 47 mm x 10 mm Measuring range 0° … 360° Resolution 12 bit Linearity error, typ. ± 1° Repeatability < 0.3° 1) Number of adjustable angles 32 Sampling rate 900 Hz Switching output 3 x PNP or IO-Link mode 2 x PNP Output function Programmable (factory setting: normally open contact) Electrical wiring DC 5-wire Working distance 1.5 mm … 4 mm 2) Magnetic misalignment ± 0.2 mm Indication LED green Static on: power on
Flashing: IO-Link mode
Flashing: find device activatedLED yellow Q1 (pin4) permanently on: contact closed
Flashing: find device activated
Flashing: Magnet too far awayLED yellow 1 Q2 (pin2) permanently on: contact closed
Flashing: find device activated
Flashing: Magnet too far awayLED yellow 2 Q3 (pin5) permanently on: contact closed
Flashing: find device activated
Flashing: Magnet too far away- 1) Ub and Ta constant.
- 2) This specification is measured with the magnets listed under accessories. The value may vary if other magnets are used.
-
Mechanics/electronics
Supply voltage 10 V DC … 30 V DC Residual ripple 10 % Voltage drop ≤ 2 V 1) Current consumption ≤ 30 mA 2) Continuous current Ia ≤ 200 mA 3) Short-circuit protection ✔ Reverse polarity protection ✔ Power-up pulse protection ✔ Connection type Cable with male connector Material, cable PUR Conductor cross section 0.34 mm² Cable diameter 4.8 mm Housing material Plastic (PPS) Tightening torque Typ. 1 Nm Protection class III UL File No. E181493 DCavg 0 % - 1) At Ia max.
- 2) Without load.
- 3) Per output.
-
Communication interface
Communication interface IO-Link V1.1 Communication Interface detail COM3 (230,4 kBaud) Cycle time ≥ 1 ms Process data length 4 Byte Process data structure See “Addendum to operating instructions document number 8024987” Factory setting Angle ranges: 0…120 Qint1 = Q1, 120…240 Qint2 = Q2, 240…359.9 Qint3 = Q3
Output: normally open contact
Time delay: deactivated
-
Ambient data
EMC EN 61000-4-2 ESD: 4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated: 10 Veff
EN 61000-4-4 burst: 2 kV
EN 61000-4-6 HF wire-bound: 10 Veff
Enclosure rating IP67 (EN 60529) 1)
IP68 (EN 60529) 1)
Operating temperature range –40 °C … +80 °C Resistance to shocks 100 g, 6 shocks, 6 ms (EN 60068-2-27) Continuous shock 40 g, 6 ms, 8,000 shocks (EN 60068-2-29) Resistance to vibration 15 g, 5 Hz … 2,000 Hz, 120 minutes (EN 60068-2-6) - 1) IPx8 = 168h, 1m.
-
Smart Task
Smart Task name Base logics Timer function Deactivated
On delay
Off delay
ON and OFF delay
Impulse (one shot)
Inverter Yes Switching signal Switching signal QL1 Switching output Switching signal QL2 Switching output Switching signal QL3 Switching output
-
Classifications
eCl@ss 5.0 27270502 eCl@ss 5.1.4 27270502 eCl@ss 6.0 27270590 eCl@ss 6.2 27270590 eCl@ss 7.0 27270502 eCl@ss 8.0 27270502 eCl@ss 8.1 27270502 eCl@ss 9.0 27270502 eCl@ss 10.0 27270502 eCl@ss 11.0 27270502 eCl@ss 12.0 27270502 ETIM 5.0 EC001486 ETIM 6.0 EC001486 ETIM 7.0 EC001486 ETIM 8.0 EC001486 UNSPSC 16.0901 41112113