Mechanics/electronics
Supply voltage Vs DC 18 V … 30 V, limit values Ripple 5 Vpp 1) Initialization time Typ. 1.5 s 2) Housing material Metal (Aluminum die cast) Window material Plastic (PMMA) Connection type Male connector, M12, SPEEDCON™ compatible Indication 6 digit 5 x 7 dot matrix display, LEDs Weight Approx. 800 g (with mounting bracket: approx. 1,600 g) Current consumption At 24 V DC < 1,000 mA Dimensions (W x H x D) 69.4 mm x 82.5 mm x 100.2 mm Modulation frequency Fix Enclosure rating IP65 Protection class III - 1) May not fall short of or exceed VS tolerances.
- 2) After loss of reflector < 40 ms.
-
Performance
Measuring range 0.15 m … 100 m, on “diamond grade” reflective tape Target Reflector Resolution 0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm Repeatability 0.5 mm 1) Accuracy ± 2 mm 2) Response time 2 ms Measurement cycle time 1 ms Output time 1 ms Light source Laser, red 3)
visible red lightLaser class 2, complies with 21 CFR 1040.10 and 1040.11 except for the conformance according to “Laser Notice No. 50” from June 24, 2007 (IEC 60825-1:2014, EN 60825-1:2014) Typ. light spot size (distance) 5 mm + (2 mm x distance in m) Max. movement speed 15 m/s Acceleration (max.) ≤ 15 m/s² Heating ✔ - 1) Statistical error 1 σ, environmental conditions constant, min. warm-up time 10 min.
- 2) From 150 mm … 180 mm measuring range the accuracy can reach ± 4 mm.
- 3) Average service life: 100,000 h at TU = +25 °C.
-
Interfaces
EtherNet/IP™ ✔ Digital output Number 2 1) Type Push-pull: PNP/NPN Function Distance: Distance switching output Speed; Speed output Service: Warning message as the sensor ages, if the damping value is exceeded (for example when contaminated, if the permitted interior device temperature is exceeded or undercut, if the measured value has a plausibility error, if the laser is not ready for operation, if the heating is switched on Laser off Preset Maximum output current IA ≤ 100 mA 2) Multifunctional input (MF) 1 x MF1 3) - 1) HIGH = > VS – 3 V / LOW = < 2 V.
- 2) Max. 100 nF/20 mH.
- 3) HIGH > 12 V / LOW < 3 V.
-
Ambient data
Electromagnetic compatibility (EMC) EN 61000-6-2, EN 61000-6-4 1) Ambient temperature, operation –40 °C … +55 °C, operation with heating 2)
–40 °C … +75 °C, operation with cooling case 2)
Ambient temperature, storage –40 °C … +75 °C Effect of air pressure 0.3 ppm/hPa Effect of air temperature 1 ppm/K Temperature drift Typ. 0.1 mm/K Typ. Ambient light immunity ≤ 100,000 lx Mechanical load Shock: (EN 600 68-2-27)
Sine: (EN 600 68-2-6)
Noise: (EN 600 68-2-64)
- 1) This is a Class A device. This device can cause radio interference in living quarters.
- 2) Temperatures < –10 °C require warm-up time of typ. 7 minutes.
-
Classifications
ECl@ss 5.0 27270801 ECl@ss 5.1.4 27270801 ECl@ss 6.0 27270801 ECl@ss 6.2 27270801 ECl@ss 7.0 27270801 ECl@ss 8.0 27270801 ECl@ss 8.1 27270801 ECl@ss 9.0 27270801 ECl@ss 10.0 27270801 ECl@ss 11.0 27270801 ETIM 5.0 EC001825 ETIM 6.0 EC001825 ETIM 7.0 EC001825 ETIM 8.0 EC001825 UNSPSC 16.0901 41111613