Features
Housing Cylindrical thread design Housing Standard design Thread size M18 x 1 Diameter Ø 18 mm Sensing range Sn 8 mm Safe sensing range Sa 6.48 mm Installation type Quasi-flush 1) Switching frequency 1,000 Hz Connection type Male connector M12, 4-pin 2) Switching output PNP Output function NO Electrical wiring DC 3-wire Enclosure rating IP67 3) Special features Resistant to cleaning agents, Visual adjustment indicator, IO-Link Special applications Hygienic and washdown zones, Difficult application conditions, Explosive areas Items supplied Mounting nut, V4A stainless steel (2x)
Cable housing/cover
- 1) When installed in conductive materials, the sensors must protrude by distance E (E = 2 mm).
- 2) With gold plated contact pins.
- 3) According to EN 60529.
-
Mechanics/electronics
Supply voltage 10 V DC … 30 V DC Ripple ≤ 10 % Voltage drop ≤ 2 V 1) Hysteresis 3 % … 20 % Reproducibility ≤ 2 % 2) 3) Temperature drift (of Sr) ± 10 % EMC According to EN 60947-5-2 Continuous current Ia ≤ 200 mA 4) No load current ≤ 10 mA Short-circuit protection ✔ Reverse polarity protection ✔ Power-up pulse protection ✔ Shock and vibration resistance 100 g / 2 ms / 500 cycles; 150 g / 1 Mio cycles; 10 Hz … 55 Hz / 1 mm; 55 Hz … 500 Hz / 60 g Ambient operating temperature –20 °C … +90 °C Housing material Stainless steel V4A, DIN 1.4404 / AISI 316L Sensing face material Plastic, LCP Housing length 65 mm Thread length 47 mm Tightening torque, max. Typ. 90 Nm ATEX marking II 3G Ex ec IIC T4 Gc X, II 3D Ex tc T135°C Dc X Ex area category 3G, 3D Protection class III UL File No. E181493 - 1) At Ia max.
- 2) Ub and Ta constant.
- 3) Of Sr.
- 4) Depend on ambient temperature. For details see operating instructions under „performance data of the sensor“.
-
Safety-related parameters
MTTFD 1,971 years DCavg 0 % TM (mission time) 20 years
-
Communication interface
Communication interface IO-Link V1.0 Communication Interface detail COM2 (38,4 kBaud) Process data length 1 Byte Process data structure Bit 0 = Sr reached
Bit 1 = Sa reached
-
Reduction factors
Note The values are reference values which may vary Stainless steel (V2A, 304) Approx. 0.55 Aluminum (Al) Approx. 0.24 Copper (Cu) Approx. 0.19 Brass (Br) Approx. 0.24
-
Installation note
Remark Associated graphic see “Installation” A 9 mm B 18 mm C 18 mm D 24 mm E 2 mm F 64 mm
-
Classifications
eCl@ss 5.0 27270101 eCl@ss 5.1.4 27270101 eCl@ss 6.0 27270101 eCl@ss 6.2 27270101 eCl@ss 7.0 27270101 eCl@ss 8.0 27270101 eCl@ss 8.1 27270101 eCl@ss 9.0 27270101 eCl@ss 10.0 27270101 eCl@ss 11.0 27270101 eCl@ss 12.0 27274001 ETIM 5.0 EC002714 ETIM 6.0 EC002714 ETIM 7.0 EC002714 ETIM 8.0 EC002714 UNSPSC 16.0901 39122230