Performance
Pulses per revolution 1,000 Measuring step 90°, electric/pulses per revolution Measuring step deviation ± 18° / pulses per revolution Error limits ± 54° / pulses per revolution Duty cycle ≤ 0.5 ± 5 %
-
Interfaces
Communication interface Incremental Communication Interface detail TTL / RS-422 Number of signal channels 6-channel Initialization time < 3 ms Output frequency ≤ 300 kHz Load current ≤ 30 mA Power consumption ≤ 0.5 W (without load)
-
Electrical data
Connection type Cable, 8-wire, universal, 1.5 m Supply voltage 7 … 30 V Reference signal, number 1 Reference signal, position 90°, electric, logically gated with A and B Reverse polarity protection ✔ Short-circuit protection of the outputs ✔ 1) MTTFd: mean time to dangerous failure 600 years (EN ISO 13849-1) 2) - 1) The short-circuit rating is only given if Us and GND are connected correctly.
- 2) This product is a standard product and does not constitute a safety component as defined in the Machinery Directive. Calculation based on nominal load of components, average ambient temperature 40°C, frequency of use 8760 h/a. All electronic failures are considered hazardous. For more information, see document no. 8015532.
-
Mechanical data
Mechanical design Blind hollow shaft Shaft diameter 8 mm 1) Weight + 150 g (with connecting cable) Shaft material Stainless steel Flange material Aluminum Housing material Aluminum Material, cable PVC Start up torque + 0.5 Ncm (+20 °C) Operating torque 0.4 Ncm (+20 °C) Permissible movement static ± 0.3 mm (radial)
± 0.5 mm (axial) 2)
Permissible movement dynamic ± 0.1 mm (radial)
± 0.2 mm (axial) 2)
Operating speed 6,000 min⁻¹ 3) Maximum operating speed ≤ 8,000 min⁻¹ 4) Moment of inertia of the rotor 0.8 gcm² Bearing lifetime 2 x 10^9 revolutions Angular acceleration ≤ 500,000 rad/s² - 1) Order collets for 5 mm, 6 mm and 1/4” mm separately as accessories.
- 2) Higher values are possible using limited bearing life.
- 3) Allow for self-heating of 4.7 K per 1,000 rpm when designing the operating temperature range.
- 4) No permanent operation. Decreasing signal quality.
-
Ambient data
EMC According to EN 61000-6-2 and EN 61000-6-3 (class A) Enclosure rating IP65 Permissible relative humidity 90 % (Condensation not permitted) Operating temperature range –20 °C … +85 °C, –35 °C … +95 °C on request Storage temperature range –40 °C … +100 °C, without package Resistance to shocks 100 g, 6 ms (EN 60068-2-27) Resistance to vibration 20 g, 10 Hz … 2,000 Hz (EN 60068-2-6)
-
Classifications
eCl@ss 5.0 27270501 eCl@ss 5.1.4 27270501 eCl@ss 6.0 27270590 eCl@ss 6.2 27270590 eCl@ss 7.0 27270501 eCl@ss 8.0 27270501 eCl@ss 8.1 27270501 eCl@ss 9.0 27270501 eCl@ss 10.0 27270501 eCl@ss 11.0 27270501 eCl@ss 12.0 27270501 ETIM 5.0 EC001486 ETIM 6.0 EC001486 ETIM 7.0 EC001486 ETIM 8.0 EC001486 UNSPSC 16.0901 41112113