Features
Housing Cylindrical thread design Housing Short-body Thread size M8 x 1 Diameter Ø 8 mm Sensing range Sn 4 mm Safe sensing range Sa 3.24 mm Installation type Non-flush Switching frequency 4,000 Hz Connection type Cable, 3-wire, 5 m Switching output NPN Output function NO Electrical wiring DC 3-wire Enclosure rating IP67 1) Items supplied Mounting nut, brass, nickel-plated (2x) - 1) According to EN 60529.
-
Mechanics/electronics
Supply voltage 10 V DC … 30 V DC Ripple ≤ 10 % Voltage drop ≤ 2 V 1) Time delay before availability ≤ 100 ms Hysteresis 5 % … 15 % Reproducibility ≤ 2 % 2) 3) Temperature drift (of Sr) ± 10 % EMC According to EN 60947-5-2 Continuous current Ia ≤ 200 mA No load current ≤ 10 mA Cable material PVC Conductor size 0.25 mm² Cable diameter Ø 3.9 mm Short-circuit protection ✔ Reverse polarity protection ✔ Power-up pulse protection ✔ Shock and vibration resistance 30 g, 11 ms/10 Hz … 55 Hz, 1 mm Ambient operating temperature –25 °C … +75 °C Housing material Brass, nickel-plated Sensing face material Plastic, PA 66 Housing length 43 mm Thread length 21 mm Tightening torque, max. ≤ 5 Nm UL File No. NRKH.E181493 - 1) At Ia max.
- 2) Ub and Ta constant.
- 3) Of Sr.
-
Safety-related parameters
MTTFD 1,735 years DCavg 0 %
-
Reduction factors
Note The values are reference values which may vary St37 steel (Fe) 1 Stainless steel (V2A, 304) Approx. 0.8 Aluminum (Al) Approx. 0.45 Copper (Cu) Approx. 0.4 Brass (Br) Approx. 0.4
-
Installation note
Remark Associated graphic see “Installation” A 8 mm B 18 mm C 8 mm D 12 mm E 8 mm F 32 mm
-
Classifications
eCl@ss 5.0 27270101 eCl@ss 5.1.4 27270101 eCl@ss 6.0 27270101 eCl@ss 6.2 27270101 eCl@ss 7.0 27270101 eCl@ss 8.0 27270101 eCl@ss 8.1 27270101 eCl@ss 9.0 27270101 eCl@ss 10.0 27270101 eCl@ss 11.0 27270101 eCl@ss 12.0 27274001 ETIM 5.0 EC002714 ETIM 6.0 EC002714 ETIM 7.0 EC002714 ETIM 8.0 EC002714 UNSPSC 16.0901 39122230