Features
Functional principle Ultrasonic detection principle Dimensions (W x H x D) 20 mm x 37.4 mm x 70 mm Housing design Fork shaped Fork width 2.6 mm Fork depth 42.5 mm Minimum detectable object (MDO) Label size: 2 mm 1)
Label gap: 1 mm 1)
Label detection ✔ Adjustment Teach-in button (Teach-in, sensitivity, light/dark switching)
Cable (Teach-in dynamic)
Teach-in mode 1-point teach-in
2-point teach-in
Teach-in dynamic
- 1) Depends on the label thickness.
-
Mechanics/electronics
Supply voltage 10 V DC … 30 V DC 1) Ripple < 10 % 2) Current consumption 50 mA 3) Switching frequency 1.1 kHz 4) Response time 440 µs 5) Jitter 40 µs Switching output Push-pull: PNP/NPN Switching output (voltage) Push-pull: PNP/NPN High = UV – < 2 V/Low: ≤ 2 V Switching mode Light/dark switching Output current Imax. 100 mA 6) Initialization time 100 ms Connection type Cable open end, 4-wire, 2 m Cable diameter Ø 3.5 mm Protection class III 7) Circuit protection UV connections, reverse polarity protected
Output Q short-circuit protected
Interference pulse suppression
Enclosure rating IP65 Weight Approx. 100 g Housing material Metal, Zamak
Plastic, Glass fiber reinforced plastic
Indication LED indicator green: power on
LED indicator, yellow: Status switching output Q
- 1) Limit values, reverse-polarity protected, operation in short-circuit protected network: max. 8 A.
- 2) May not exceed or fall below Uv tolerances.
- 3) Without load.
- 4) With light/dark ratio 1:1.
- 5) Signal transit time with resistive load.
- 6) Output current minimal 0.03 mA.
- 7) Reference voltage DC 50 V.
-
Communication interface
IO-Link ✔ , V1.1 Data transmission rate COM3 (230,4 kBaud) Cycle time 4 ms VendorID 26 DeviceID HEX 0x8002A6 DeviceID DEC 8389286 Process data length 16 Bit Process data structure A Bit 0 = switching signal QL1
Bit 1 = switching signal QL2
Bit 2 = switching signal QInt1
Bit 3 = switching signal QInt2
Bit 4 = alarm QoR
Bit 5 = Teach busy
Bit 6 … 15 = measured value
Digital output Q1 Number 1
-
Ambient data
Ambient operating temperature +5 °C … +55 °C 1) Ambient temperature, storage –20 °C … +70 °C Shock load According to EN 60068-2-27 EMC EN 60947-5-2 2) UL File No. NRKH.E191603 & NRKH7.E191603 - 1) Do not bend below 0 °C.
- 2) The sensor complies with the Radio Safety Requirements (EMC) for the industrial sector (Radio Safety Class A). It may cause radio interference if used in a residential area.
-
Smart Task
Smart Task name Base logics
-
Classifications
eCl@ss 5.0 27270909 eCl@ss 5.1.4 27270909 eCl@ss 6.0 27270909 eCl@ss 6.2 27270909 eCl@ss 7.0 27270909 eCl@ss 8.0 27270909 eCl@ss 8.1 27270909 eCl@ss 9.0 27270909 eCl@ss 10.0 27270909 eCl@ss 11.0 27270909 eCl@ss 12.0 27270909 ETIM 5.0 EC002720 ETIM 6.0 EC002720 ETIM 7.0 EC002720 ETIM 8.0 EC002720 UNSPSC 16.0901 39121528
-
Connection/pin assignment
Connection type Cable open end, 4-wire, 2 m Connection type Detail Cable diameter Ø 3.5 mm Conductor cross section 0.14 mm² Cable material PVC Length of cable 2 m Pin assignment BN + (L+) WH MF BU – (M) BK Q/C