Features
Dimensions (W x H x D) 25 mm x 77.8 mm x 63 mm Housing design (light emission) Rectangular Sensing range max. 0 mm … 65 mm, Proximity system 1) 2)
0 mm … 110 mm, Proximity system 1) 3)
0 mm … 800 mm, Through-beam system 2)
Sensing range 0 mm … 50 mm, Proximity system 2)
0 mm … 90 mm, Proximity system 3)
0 mm … 700 mm, Through-beam system 2)
Type of light Visible red light Light source LED 4) Adjustment Potentiometer, 270° Indication LED - 1) Object with 90 % reflectance (referred to standard white, DIN 5033).
- 2) LIS/LIB.
- 3) With special fibre-optic cable.
- 4) Average service life: 100,000 h at TU = +25 °C.
-
Mechanics/electronics
Supply voltage 12 V DC … 240 V DC 1)
24 V AC … 240 V AC 1)
Power consumption ≤ 5 VA Switching output Relay, electrically isolated 2) Output function NO Switching mode Light/dark switching 2) Switching mode selector Selectable via light/dark selector Switching current (switching voltage) 3 A (240 V AC)
3 A (30 V DC)
Response time ≤ 20 ms Switching frequency 25 Hz 3) Connection type Cable gland Circuit protection A 4)
C 5)
Protection class II 6) Weight 120 g Housing material Plastic, ABS Enclosure rating IP66 Items supplied Mounting bracket BEF-W260 Usage category AC-15, DC-13, according to EN 60947-1 Ambient operating temperature –25 °C … +55 °C Ambient temperature, storage –40 °C … +70 °C UL File No. NRNT2.E128350 & NRNT8.E128350 - 1) ±10 %.
- 2) Provide suitable spark suppression for inductive or capacitive loads.
- 3) With light/dark ratio 1:1.
- 4) A = VS connections reverse-polarity protected.
- 5) C = interference suppression.
- 6) Rated voltage: 250 V AC/DC.
-
Classifications
ECl@ss 5.0 27270905 ECl@ss 5.1.4 27270905 ECl@ss 6.0 27270905 ECl@ss 6.2 27270905 ECl@ss 7.0 27270905 ECl@ss 8.0 27270905 ECl@ss 8.1 27270905 ECl@ss 9.0 27270905 ECl@ss 10.0 27270905 ECl@ss 11.0 27270905 ETIM 5.0 EC002651 ETIM 6.0 EC002651 ETIM 7.0 EC002651 ETIM 8.0 EC002651 UNSPSC 16.0901 39121528