Bus system easyNet on board
customized laser inscription or delivery with user program possible with EASY-COMBINATION-* product (article No. 2010781)
Relays: 6; analog: 1
Networkable (easyNet)
Bus system easyNet on board
customized laser inscription or delivery with user program possible with EASY-COMBINATION-* product (article No. 2010781)
Bus system easyNet on board
customized laser inscription or delivery with user program possible with EASY-COMBINATION-* product (article No. 2010781)
Relays: 6; analog: 1
Networkable (easyNet)
UL
EAC
-40 – +70 °C
5 – 95 %
constant amplitude 0.15 mm: 10 – 57
constant acceleration 2 g: 57 – 150 Hz
1.4 – 2 GHz: 3
2.0 – 2.7 GHz: 1 V/m
1 kV (supply cables, symmetrical)
② Service life (years)
≤ 20 ms
between digital inputs: no
from the outputs: yes
to interface/memory card: no
to easyLink: no
to easyNet: yes
Signal 1: ≧ 15 (I1 – I6, I9, I10), ≧ 8 (I7, I8, I11, I12) V DC
I7, I8, I11, I12: 2.2 (at 24 V DC) mA
normally 0.025 (0 -> 1/1 -> 0, Debounce OFF, I1 – I4)
normally 0.25 (0 -> 1/1 -> 0, Debounce OFF, I5, I6, I9, I10)
normally 0.15 (0 -> 1/1 -> 0, Debounce OFF, I7, I8, I11, I12) ms
between digital inputs: no
from the outputs: yes
to interface/memory card: no
to easyLink: no
to easyNet: yes
0.01 V digital
10 Bit (value 0 – 1023)
To the digital inputs: no
From the digital outputs: yes
to interface/memory card: yes
to easyNet: yes
to easyLink: yes
10 Bit (value 0 – 1023) digital
From the inputs: yes
between digital inputs: yes
to the interface: yes
to easyLink: yes
to easyNet: yes
Safe isolation according to EN 50178: 300 V AC
Basic isolation: 600 V AC
300 between two contacts V AC
500 KBit/s, 25 m
250 Kbit/s, 40 m
125 Kbit/s, 300 m
50 KBit/s, 300 m
20 KBit/s, 700 m
10 KBit/s, 1000 m
Lengths from 40 m can be obtained only with cables with reinforced cross-section and terminal adapter.
From the inputs: yes
from the outputs: yes
to easyLink: yes
to the interface: yes
up to 600 m, < 26 mΩ/m: 0.75 – 0.8 (AWG: 18)
up to 600 m, < 26 mΩ/m: 0.5 – 0.6 (AWG: 20, 19)
up to 400 m, < 40 mΩ/m: 0.34 – 0.5 (AWG: 22, 21, 20)
up to 250 m, < 60 mΩ/m: 0.25 – 0.34 (AWG: 23, 22)
up to 175 m, < 70 mΩ/m: 0.13 (AWG: 26)
up to 40 m, < 140 mΩ/m: 1.5 (AWG: 16)
UL
EAC
-40 – +70 °C
5 – 95 %
constant amplitude 0.15 mm: 10 – 57
constant acceleration 2 g: 57 – 150 Hz
1.4 – 2 GHz: 3
2.0 – 2.7 GHz: 1 V/m
1 kV (supply cables, symmetrical)
② Service life (years)
≤ 20 ms
between digital inputs: no
from the outputs: yes
to interface/memory card: no
to easyLink: no
to easyNet: yes
Signal 1: ≧ 15 (I1 – I6, I9, I10), ≧ 8 (I7, I8, I11, I12) V DC
I7, I8, I11, I12: 2.2 (at 24 V DC) mA
normally 0.025 (0 -> 1/1 -> 0, Debounce OFF, I1 – I4)
normally 0.25 (0 -> 1/1 -> 0, Debounce OFF, I5, I6, I9, I10)
normally 0.15 (0 -> 1/1 -> 0, Debounce OFF, I7, I8, I11, I12) ms
between digital inputs: no
from the outputs: yes
to interface/memory card: no
to easyLink: no
to easyNet: yes
0.01 V digital
10 Bit (value 0 – 1023)
To the digital inputs: no
From the digital outputs: yes
to interface/memory card: yes
to easyNet: yes
to easyLink: yes
10 Bit (value 0 – 1023) digital
From the inputs: yes
between digital inputs: yes
to the interface: yes
to easyLink: yes
to easyNet: yes
Safe isolation according to EN 50178: 300 V AC
Basic isolation: 600 V AC
300 between two contacts V AC
500 KBit/s, 25 m
250 Kbit/s, 40 m
125 Kbit/s, 300 m
50 KBit/s, 300 m
20 KBit/s, 700 m
10 KBit/s, 1000 m
Lengths from 40 m can be obtained only with cables with reinforced cross-section and terminal adapter.
From the inputs: yes
from the outputs: yes
to easyLink: yes
to the interface: yes
up to 600 m, < 26 mΩ/m: 0.75 – 0.8 (AWG: 18)
up to 600 m, < 26 mΩ/m: 0.5 – 0.6 (AWG: 20, 19)
up to 400 m, < 40 mΩ/m: 0.34 – 0.5 (AWG: 22, 21, 20)
up to 250 m, < 60 mΩ/m: 0.25 – 0.34 (AWG: 23, 22)
up to 175 m, < 70 mΩ/m: 0.13 (AWG: 26)
up to 40 m, < 140 mΩ/m: 1.5 (AWG: 16)