Bus system easyNet on board
customized laser inscription or delivery with user program possible with EASY-COMBINATION-* product (article No. 2010781)
Networkable (easyNet)
Bus system easyNet on board
customized laser inscription or delivery with user program possible with EASY-COMBINATION-* product (article No. 2010781)
Bus system easyNet on board
customized laser inscription or delivery with user program possible with EASY-COMBINATION-* product (article No. 2010781)
Networkable (easyNet)
UL
EAC
-40 – +70 °C
5 – 95 %
constant amplitude 0.15 mm: 10 – 57
constant acceleration 2 g: 57 – 150 Hz
1.4 – 2 GHz: 3
2.0 – 2.7 GHz: 1 V/m
1 kV (supply cables, symmetrical)
② Service life (years)
normally 35 mA at 230/240 V AC 50 Hz
≤ 20 ms
between digital inputs: no
from the outputs: yes
to the interface: yes
to easyNet: yes
to easyLink: yes
Signal 1: 79 – 264 V AC
I7, I8: 2 x 4 (at 115 V AC, 60 Hz)
I1 – I6, I9 – I12: 10 x 0.5 (at 230 V AC, 50 Hz)
I7, I8: 2 x 6 (at 230 V AC, 50 Hz) mA
20⁄16⅔ (0 – > 1/1 -> 0, debounce OFF 50/60Hz, I1 – I6, I9 – I12)
120/100 (1 -> 0, debounce ON 50/60Hz, I7, I8)
40⁄33⅔ (1 -> 0, debounce OFF 50/60Hz, I7, I8)
80⁄66⅔ (0 -> 1, debounce ON 50/60Hz, I7, I8)
20⁄16⅔ (0 – > 1, debounce OFF 50/60Hz, I7, I8) ms
≤ 60 per input (I1 – I6, I9 – I12, Debounce OFF)
≤ 100 per input (I7, I8) m
From the inputs: yes
between digital inputs: yes
to the interface: yes
to easyLink: yes
to easyNet: yes
Safe isolation according to EN 50178: 300 V AC
Basic isolation: 600 V AC
300 between two contacts V AC
500 KBit/s, 25 m
250 Kbit/s, 40 m
125 Kbit/s, 300 m
50 KBit/s, 300 m
20 KBit/s, 700 m
10 KBit/s, 1000 m
Lengths from 40 m can be obtained only with cables with reinforced cross-section and terminal adapter.
From the inputs: yes
from the outputs: yes
to easyLink: yes
to the interface: yes
up to 600 m, < 26 mΩ/m: 0.75 – 0.8 (AWG: 18)
up to 600 m, < 26 mΩ/m: 0.5 – 0.6 (AWG: 20, 19)
up to 400 m, < 40 mΩ/m: 0.34 – 0.5 (AWG: 22, 21, 20)
up to 250 m, < 60 mΩ/m: 0.25 – 0.34 (AWG: 23, 22)
up to 175 m, < 70 mΩ/m: 0.13 (AWG: 26)
up to 40 m, < 140 mΩ/m: 1.5 (AWG: 16)
UL
EAC
-40 – +70 °C
5 – 95 %
constant amplitude 0.15 mm: 10 – 57
constant acceleration 2 g: 57 – 150 Hz
1.4 – 2 GHz: 3
2.0 – 2.7 GHz: 1 V/m
1 kV (supply cables, symmetrical)
② Service life (years)
normally 35 mA at 230/240 V AC 50 Hz
≤ 20 ms
between digital inputs: no
from the outputs: yes
to the interface: yes
to easyNet: yes
to easyLink: yes
Signal 1: 79 – 264 V AC
I7, I8: 2 x 4 (at 115 V AC, 60 Hz)
I1 – I6, I9 – I12: 10 x 0.5 (at 230 V AC, 50 Hz)
I7, I8: 2 x 6 (at 230 V AC, 50 Hz) mA
20⁄16⅔ (0 – > 1/1 -> 0, debounce OFF 50/60Hz, I1 – I6, I9 – I12)
120/100 (1 -> 0, debounce ON 50/60Hz, I7, I8)
40⁄33⅔ (1 -> 0, debounce OFF 50/60Hz, I7, I8)
80⁄66⅔ (0 -> 1, debounce ON 50/60Hz, I7, I8)
20⁄16⅔ (0 – > 1, debounce OFF 50/60Hz, I7, I8) ms
≤ 60 per input (I1 – I6, I9 – I12, Debounce OFF)
≤ 100 per input (I7, I8) m
From the inputs: yes
between digital inputs: yes
to the interface: yes
to easyLink: yes
to easyNet: yes
Safe isolation according to EN 50178: 300 V AC
Basic isolation: 600 V AC
300 between two contacts V AC
500 KBit/s, 25 m
250 Kbit/s, 40 m
125 Kbit/s, 300 m
50 KBit/s, 300 m
20 KBit/s, 700 m
10 KBit/s, 1000 m
Lengths from 40 m can be obtained only with cables with reinforced cross-section and terminal adapter.
From the inputs: yes
from the outputs: yes
to easyLink: yes
to the interface: yes
up to 600 m, < 26 mΩ/m: 0.75 – 0.8 (AWG: 18)
up to 600 m, < 26 mΩ/m: 0.5 – 0.6 (AWG: 20, 19)
up to 400 m, < 40 mΩ/m: 0.34 – 0.5 (AWG: 22, 21, 20)
up to 250 m, < 60 mΩ/m: 0.25 – 0.34 (AWG: 23, 22)
up to 175 m, < 70 mΩ/m: 0.13 (AWG: 26)
up to 40 m, < 140 mΩ/m: 1.5 (AWG: 16)