System part Sensor head
-
Mechanics/electronics
Supply voltage Vs DC 12 V … 24 V 1) Warm-up time ≤ 5 min Housing material Metal (Aluminum) Window material Glass Connection type 0.5 m cable with connector 2) Indication LEDs, 4” color display on optional evaluation unit Weight 250 g 3) Dimensions (W x H x D) 29 mm x 78 mm x 75 mm Enclosure rating IP67 Protection class III - 1) DC 12 V (–5 %) … DC 24 V (+10 %).
- 2) Can be extended to up to 50 m with extension cable.
- 3) Includes 0.5 m cable.
-
Performance
Measuring range 25 mm … 35 mm 1) 2) Target Natural objects Repeatability 0.2 µm 3) Linearity Diffuse ± 8 µm 3)
Specular ± 4 µm 3)
Response time ≥ 0.1 ms 4) 5) Measuring frequency ≤ 10 kHz 1) 5) Output time ≥ 0.1 ms Light source Laser, red
visible red lightLaser class 2 (IEC 60825-1:2014, EN 60825-1:2014) 6) Typ. light spot size (distance) 260 µm x 1,000 µm (30 mm) Special task Thickness measurement of transparent material Additional function Mean-value setting 1 … 4,096x, selectable measuring frequency (automatic / 0.1 ms … 3.2 ms), automatic sensitivity adjustment, manual sensitivity adjustment, Mutual interference, Glass thickness measurement Thickness measurement of transparent material 0.9 mm … 5 mm - 1) 6 % … 90 % remission; at default settings.
- 2) If there are reflections, the measuring range is reduced to 23.6 mm … 28.6 mm.
- 3) Measurement at 90% remission (ceramic, white), or mirror for OD5-25x; averaging set to: 256 or 4096 for OD5-25x; constant ambient conditions.
- 4) Time needed for automatic sensitivity adjustment is calculated as: sampling period x 20. At default setting 100 µs (10kHz) this is <= 2ms.
- 5) Default setting for OD5-350×100 and OD5-500×200 = 0.8 ms, or 1.25 kHz, all others = 0.1 ms/10 kHz.
- 6) Wavelength: 658 nm, max. output: 1 mW.
-
Interfaces
Serial ✔ , RS-422 Remark RS-232 optional via external evaluation unit AOD5 Digital output Number 5 1) Type PNP / NPN Maximum output current IA ≤ 100 mA Analog output Number 3 1) 2) Type Current output / voltage output Current 4 mA … 20 mA, ≤ 300 Ω Voltage 0 V … 10 V 3) Laser-off input 1 x laser-off - 1) Optional over evaluation unit AOD5.
- 2) A maximum of three current and three voltage outputs are possible via the AOD5 evaluation unit.
- 3) Output resistance 100 Ω, min. load 10 k Ω.
-
Ambient data
Ambient temperature, operation –10 °C … +50 °C Ambient temperature, storage –20 °C … +60 °C Relative air humidity (non-condensing) 35 % … 85 % Temperature drift ± 0.01 % FS/K (FS = Full Scale = Measuring range of sensor) Typ. Ambient light immunity Artificial light: ≤ 3,000 lx
Sunlight: ≤ 10,000 lx
Vibration resistance 10 Hz … 55 Hz (amplitude 1.5 mm, x-, y-, z-axis 2 hours each) Shock resistance 50 G (x, y, z axis 3 times each)
-
General notes
Note on use OD Precision sensor head can be used in combination with AOD5-P/N1 or stand-alone via RS-422
-
Classifications
eCl@ss 5.0 27270801 eCl@ss 5.1.4 27270801 eCl@ss 6.0 27270801 eCl@ss 6.2 27270801 eCl@ss 7.0 27270801 eCl@ss 8.0 27270801 eCl@ss 8.1 27270801 eCl@ss 9.0 27270801 eCl@ss 10.0 27270801 eCl@ss 11.0 27270801 eCl@ss 12.0 27270916 ETIM 5.0 EC001825 ETIM 6.0 EC001825 ETIM 7.0 EC001825 ETIM 8.0 EC001825 UNSPSC 16.0901 41111613