Mechanics/electronics
Supply voltage Vs DC 12 V (–5 %) … DC 24 V (+10 %) Power consumption ≤ 1.92 W 1) Warm-up time ≤ 5 min Housing material Metal (Aluminum) Window material Plastic (PPSU) Connection type Male connector, M8, 4-pin Indication 4-digit 7-segment display (plus 4 LEDs for status display) Control elements 4 buttons Weight 40 g Dimensions (W x H x D) 17.8 mm x 44.4 mm x 31 mm Enclosure rating IP67 Protection class III - 1) Without load, with current output.
-
Performance
Measuring range 10 mm … 20 mm Target Natural objects Repeatability 1 µm 1) 2) Linearity ± 10 µm 3) Response time ≥ 2 ms 4) Measuring frequency ≤ 2 kHz Output time ≥ 0.5 ms Light source Laser, red
visible red lightLaser class 1 (IEC 60825-1:2014, EN 60825-1:2014) 5) Typ. light spot size (distance) 700 µm x 500 µm (15 mm) Additional function Averaging 1 … 512x, automatic or manual sensitivity adjustment, switching mode: window (Wnd), switching mode: distance to object (DtO), switiching mode: object between sensor and background (ObSB), multifunctional input: laser-off / external teach-in / trigger - 1) Averaging function set to: 512.
- 2) Constant ambient conditions.
- 3) Measurement on 90 % remission (ceramic, white).
- 4) With fixed sensitivity adjustment and averaging setting = 1. With automatic sensitivity and measuring rate 500 µs: 2 … 7.5 ms response time/measuring rate 1,000 µs: 4 … 15 ms response time.
- 5) Wavelength: 655 nm, max. output: 390 µW (laser class 1) / < 1 mW (laser class 2).
-
Interfaces
Serial ✔ , RS-485 PROFIBUS DP ✔ Type of fieldbus integration Optional, over external evaluation unit AOD1 and Gateway WI180C-PB Digital output Number 1 … 3 1) Type PNP/NPN, selectable Analog output Number 1 1) Type Current output Current 4 mA … 20 mA, ≤ 300 Ω - 1) Optional over evaluation unit AOD1.
-
Ambient data
Ambient temperature, operation –10 °C … +50 °C Ambient temperature, storage –20 °C … +60 °C Min. rel. humidity (not condensing) 35 % Max. rel. humidity (not condensing) 95 % Temperature drift ± 0.08 % FS/K (FS = Full Scale = Measuring range of sensor) Typ. Ambient light immunity Artificial light: ≤ 3,000 lx
Sunlight: ≤ 10,000 lx
Vibration resistance 10 Hz … 55 Hz (amplitude 1.5 mm, x-, y-, z-axis 2 hours each) Shock resistance 50 G (x, y, z axis 3 times each)
-
General notes
Note on use The sensor head can be used with evaluation unit AOD1 or stand-alone via RS-485 Note Not free of paint wetting impairment substances.
-
Classifications
eCl@ss 5.0 27270801 eCl@ss 5.1.4 27270801 eCl@ss 6.0 27270801 eCl@ss 6.2 27270801 eCl@ss 7.0 27270801 eCl@ss 8.0 27270801 eCl@ss 8.1 27270801 eCl@ss 9.0 27270801 eCl@ss 10.0 27270801 eCl@ss 11.0 27270801 eCl@ss 12.0 27270916 ETIM 5.0 EC001825 ETIM 6.0 EC001825 ETIM 7.0 EC001825 ETIM 8.0 EC001825 UNSPSC 16.0901 41111613