Key Commercial Data
Orderkey | 2880134 |
---|---|
Packing unit | 1 pc |
Note | Made to Order (non-returnable) |
Catalog page | Page 143 (C-4-2017) |
GTIN | 4017918962784 |
Weight per Piece (excluding packing) | 3,062.580 g |
Custom tariff number | 85363010 |
Country of origin | DE (Germany) |
General
Housing material | Sheet steel |
---|---|
Color | beige |
Standards for cearances and creepage distances | DIN VDE 0110-1 |
IEC 60664-1 | |
Overvoltage category | II |
Degree of pollution | 2 |
Mounting type | 19″ rack |
Type | 19″ rack patch module |
Number of positions | 20 |
Direction of action | Line-Line & Line-Signal Ground/Shield & Signal Ground/Shield-Earth Ground |
Protective circuit
IEC test classification | C1 |
---|---|
C2 | |
C3 | |
B3 | |
Maximum continuous voltage UC | 6 V DC (Core – core) |
Maximum continuous voltage UC(line-earth) | 68 V DC (optional: +/- 6 V DC) |
Rated current | 1.5 A (25 °C) |
Operating effective current ICat UC | ≤ 1 mA |
Residual current IPE | ≤ 1 mA (jumper 2 unplugged) |
Nominal discharge current In(8/20) µs (line-line) | 350 A |
Nominal discharge current In(8/20) µs (line-earth) | 350 A |
Nominal discharge current In(8/20) µs (shield-earth) | 2.5 kA (with insulated housing) |
Total discharge current Itotal(8/20) µs | 10 kA |
Nominal pulse current Ian (10/1000) µs (line-line) | 100 A |
Nominal pulse current Ian (10/1000) µs (line-earth) | 100 A |
Output voltage limitation at 1 kV/µs (line-line) static | ≤ 20 V |
Output voltage limitation at 1 kV/µs (line-earth) static | ≤ 30 V (J2 plugged) |
≤ 170 V (J2 unplugged) | |
Output voltage limitation at 1 kV/µs (shield-earth) static | ≤ 700 V (with insulated shield) |
Residual voltage at In(line-line) | ≤ 65 V |
Residual voltage at In(line-earth) | ≤ 45 V (J2 ON) |
≤ 220 V (J2 OFF) | |
Residual voltage at In(shield-earth) | ≤ 700 V |
Voltage protection level Up(line-line) | ≤ 50 V (C1 – 500 V / 250 A) |
Voltage protection level Up(line-earth) | ≤ 40 V (C1 – 500 V / 250 A (J2 ON)) |
≤ 180 V (C1 – 500 V / 250 A (J2 OFF)) | |
Voltage protection level Up(shield-ground) | ≤ 800 V (with insulated housing) |
Response time tA(line-line) | ≤ 1 ns |
Response time tA(line-earth) | ≤ 1 ns |
Response time tA (line-shield) | ≤ 100 ns |
Input attenuation aE, sym. | typ. 1 dB (≤ 100 MHz) |
Near-end crosstalk attenuation | typ. 36 dB (100 Ω system / 100 MHz) |
Cut-off frequency fg (3 dB), sym. in 100 Ohm system | > 100 MHz |
Capacity (line-line) | typ. 20 pF |
Capacity (line-earth) | typ. 1 pF |
Surge protection fault message | none |
Impulse durability (line-line) | C1 – 500 V / 250 A |
Impulse durability (line-earth) | C1 – 500 V / 250 A |
Impulse durability (shield-earth) | C2 (4 kV / 2 kA) |
Connection data
Connection method | RJ45 |
---|---|
Connection method IN | RJ45 socket |
Connection method OUT | RJ45 socket |
Connection technology | Network interfaces (e.g. Ethernet, Token Ring and CDDI/FDDI) |