Features
Functional principle Photoelectric proximity sensor Functional principle detail Background suppression Sensing range Sensing range min. 0.005 m Sensing range max. 3 m Adjustable switching threshold for background suppression 0.1 m … 3 m Reference object Object with 90% remission factor (complies with standard white according to DIN 5033) Minimum distance between set sensing range and background (black 6% / white 90%) 200 mm, at a distance of 1000 mm Emitted beam Light source LED Type of light Visible red light Shape of light spot Rectangular Light spot size (distance) Ø 28 mm (500 mm) Maximum dispersion of the emitted beam around the standardized transmission axis (squint angle) < +/- 1.5° (at Ta = +23 °C) Key LED figures Normative reference EN 62471:2008-09 | IEC 62471:2006, modified LED risk group marking Free group Wave length 630 nm Average service life 100,000 h at Ta = +25 °C Adjustment Potentiometer For setting the sensing range, 7 rotations Indication LED green Operating indicator
Static on: power onLED yellow Status of received light beam
Static on: object present
Static off: object not present
-
Electrical data
Supply voltage UB 21.6 V AC/DC … 253 V AC/DC Ripple < 10 % Usage category DC-13 (according to EN 60947-1)
AC-15 (according to EN 60947-1)
Current consumption ≤ 10 mA, Without load. At 230 V AC/DC
≤ 45 mA, Without load. At 24 V AC/DC
Protection class II Digital output Number 2 (Complementary) Type Relay, SPDT, electrically isolated 1) Output current Imax. 3 A@250 V AC, 4 A@24 VDC, 0.22 A@250 V DC UL: 4 A@250 V AC, general use 4 A @ 250 V AC, resistive (NO) 3 A @ 250 V AC, resistive (NC) 4 A @ 24 V DC, NO, general use 3 A @ 24 V DC, NC, general use R300/B300 (NO contacts only) Response time ≤ 15 ms Switching frequency 10 Hz 2) Pin/Wire assignment BN 1 + (L+) BU 2 N WH 3 Relay COM BK 4 Relay NO
Relay output, light switching, object present → output LOWGY 5 Relay NC
Relay output, dark switching, object present → output HIGH- 1) Suitable arc suppression with inductive or capacitive load. Relay contacts are separated from the supply voltage by a basic isolation of 3.2 mm. Depending on the application, additional insulation may be required in the user wiring.
- 2) With light/dark ratio 1:1.
-
Mechanical data
Housing Rectangular Dimensions (W x H x D) 23.5 mm x 74.5 mm x 63 mm Connection Terminal connection, 5 terminals Material Housing Plastic, ABS Front screen Plastic, PMMA Weight 90 g
-
Ambient data
Enclosure rating IP67 (EN 60529) Ambient operating temperature –30 °C … +60 °C 1) Ambient temperature, storage –40 °C … +70 °C Typ. Ambient light immunity Sunlight: ≤ 20,000 lx Shock resistance 30 g, 11 ms (3 positive and 3 negative shocks along X, Y, Z axes, 18 total shocks (EN60068-2-27)) Vibration resistance 10 Hz … 1,000 Hz (Amplitude 1 mm, 3 x 30 min (EN60068-2-6)) Air humidity 35 % … 95 %, Relative humidity (no condensation) Electromagnetic compatibility (EMC) EN 60947-5-2, EN 61000-6-3 2) UL File No. NRKH.E348498 & NRKH7.E348498 - 1) The max. ambient temperature is 50 °C (UL).
- 2) The device can cause interference when it is used in a residential environment.
-
Classifications
eCl@ss 5.0 27270904 eCl@ss 5.1.4 27270904 eCl@ss 6.0 27270904 eCl@ss 6.2 27270904 eCl@ss 7.0 27270904 eCl@ss 8.0 27270904 eCl@ss 8.1 27270904 eCl@ss 9.0 27270904 eCl@ss 10.0 27270904 eCl@ss 11.0 27270904 eCl@ss 12.0 27270903 ETIM 5.0 EC002719 ETIM 6.0 EC002719 ETIM 7.0 EC002719 ETIM 8.0 EC002719 UNSPSC 16.0901 39121528