Key Commercial Data
Orderkey | 1066602 |
---|---|
Packing unit | 1 pc |
Catalog page | Page 572 (C-5-2019) |
GTIN | 4055626733906 |
Weight per Piece (excluding packing) | 0.000 g |
Custom tariff number | 85444290 |
Country of origin | DE (Germany) |
Ambient conditions
Ambient temperature (operation) | -40 °C … 70 °C (fixed installation) |
---|---|
-10 °C … 70 °C (flexible installation) | |
Ambient temperature (storage/transport) | -40 °C … 80 °C |
Maximum altitude | ≤ 2000 m |
Degree of protection | IP20 |
≥ IP54 (Installation location) |
General
Max. permissible operating voltage | 25 V AC |
---|---|
60 V DC | |
Max. current carrying capacity per path | 2 A (50 °C) |
1 A (70°C) | |
Length of cable | 2 m |
External cable diameter | 7.9 mm ±0.5 mm |
Single wire, cross section | 0.25 mm² |
Single wire, cross section [AWG] | 24 |
Single wire, number of litz wires | 14 |
Single wire, material | Cu uninsulated |
Wire diameter incl. insulation | 1.2 mm ±0.05 mm |
Smallest bending radius, fixed installation | 67 mm |
Smallest bending radius, movable installation | 126 mm |
Bending cycles | 5000 (at a radius of ≥ 15x outside diameter) |
Shielding | yes |
Tinned copper braided shield | |
Cable insulation resistance | ≥ 20 MΩ/km (at 20 °C) |
Cable resistance | ≤ 80 Ω/km (at 20 °C) |
Outer sheath, material | Halogen-free sheath |
External sheath, color | gray |
Nominal operating mode | 100% operating factor |
Connection data
Connection name | Field level |
---|---|
Connection method | D-SUB pin strip |
Screw thread | UNC 4-40 |
Number of connections | 1 |
Number of positions | 15 |
Torque | 0.2 Nm |
Insertion/withdrawal cycles | > 200 |
Connection data 2
Connection name | Controller level |
---|---|
Connection method | D-SUB socket strip |
Screw thread | UNC 4-40 |
Number of connections | 1 |
Number of positions | 15 |
Torque | 0.2 Nm |
Insertion/withdrawal cycles | > 200 |
Standards and Regulations
Flame resistance | IEC 60332-1-2 |
---|---|
VDE 0842, Part 332-1-2 | |
IEC 60332-3-22 | |
Resistance to oil | against occasional splashes |
Gasoline resistance | against occasional splashes |
Designation | Air clearances and creepage distances |
Standards/regulations | DIN EN 50178 |
Rated insulation voltage | 125 V |
Rated surge voltage | 1.2 kV |
Insulation | Functional insulation |
Pollution degree | 2 |
Overvoltage category | II |
Color code
Connector 1 = connector 2 (optional) = wire color | D-SUB15 (1) = D-SUB15 (1) = white |
---|---|
D-SUB15 (2) = D-SUB15 (2) = brown | |
D-SUB15 (3) = D-SUB15 (3) = green | |
D-SUB15 (4) = D-SUB15 (4) = yellow | |
D-SUB15 (5) = D-SUB15 (5) = gray | |
D-SUB15 (6) = D-SUB15 (6) = pink | |
D-SUB15 (7) = D-SUB15 (7) = blue | |
D-SUB15 (8) = D-SUB15 (8) = red | |
D-SUB15 (9) = D-SUB15 (9) = black | |
D-SUB15 (10) = D-SUB15 (10) = violet | |
D-SUB15 (11) = D-SUB15 (11) = gray-pink | |
D-SUB15 (12) = D-SUB15 (12) = red-blue | |
D-SUB15 (13) = D-SUB15 (13) = white-green | |
D-SUB15 (14) = D-SUB15 (14) = brown-green | |
D-SUB15 (15) = D-SUB15 (15) = white-yellow |
Environmental Product Compliance
China RoHS | Environmentally Friendly Use Period = 50 |
---|---|
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer’s declaration” |
Classifications
[email protected]
[email protected] 5.0 | 27242200 |
---|---|
[email protected] 5.1 | 27242200 |
[email protected] 6.0 | 27249200 |
[email protected] 7.0 | 27249205 |
[email protected] 8.0 | 27249205 |
[email protected] 9.0 | 27242220 |
General
Max. permissible operating voltage | 25 V AC |
---|---|
60 V DC | |
Max. current carrying capacity per path | 2 A (50 °C) |
1 A (70°C) | |
Length of cable | 2 m |
External cable diameter | 7.9 mm ±0.5 mm |
Single wire, cross section | 0.25 mm² |
Single wire, cross section [AWG] | 24 |
Single wire, number of litz wires | 14 |
Single wire, material | Cu uninsulated |
Wire diameter incl. insulation | 1.2 mm ±0.05 mm |
Smallest bending radius, fixed installation | 67 mm |
Smallest bending radius, movable installation | 126 mm |
Bending cycles | 5000 (at a radius of ≥ 15x outside diameter) |
Shielding | yes |
Tinned copper braided shield | |
Cable insulation resistance | ≥ 20 MΩ/km (at 20 °C) |
Cable resistance | ≤ 80 Ω/km (at 20 °C) |
Outer sheath, material | Halogen-free sheath |
External sheath, color | gray |
Nominal operating mode | 100% operating factor |